Wire Installation With Kl08Nsb Wiring Centre - Salus BTRP230(50) Full User Manual

Table of Contents

Advertisement

II - 3 wire installation with KL08NSB wiring centre
3 wire installation with KL08NSB wiring center. Description of the operation rules:
- BTRP230V(50) thermostat's functionality is limited because of 3 wire installation. NSB function is disabled and BTRP230V(50) thermostat doesn't work
as a MASTER thermostat - no effect on other thermostats like BTR230V(20)
- schedules can be set individually on each BTRP230V(50) thermostats if system is equipped with more than one BTRP230V(50) thermostat
PLEASE NOTE!
The same operating rules apply to wiring center KL06.
BTRP230(50)
BTRP230(50)
BTRP230(50)
Power Supply
230V AC
3 wires x 0.75 mm2
KL08NSB
KL04NSB (optional)
Actuators wires
Pump control wires
Boiler control wires
2 x 0.75 mm2
2 x 1 mm2
2 x 1 mm2
T30NC230
THB23030
PUMP (optional)
BOILER
12