I A - 4 Wire Installation With Kl08Nsb Wiring Centre - Salus HTRP230V Full User Manual

Table of Contents

Advertisement

I A - 4 wire installation with KL08NSB wiring centre

When HTRP230V(50) thermostat works as a MASTER (group controller) it means it takes control of SLAVE thermostats e.g. HTRS230V(30), HTR230V(20).
MASTER thermostat controls SLAVE thermostat only when SLAVE thermostat is in AUTO mode. Comfort (SUN) and economy (MOON) setpoint
temperatures are set individually on each thermostat but switching between those temperature is based on time schedule taken from HTRP230(50)
thermostat which works like a group controller. Functions such as: setpoint temperature change, holiday mode, party mode or frost protection mode are
not managed by MASTER thermostat.
MASTER
SLAVE
HTRP230(50)
HTRS230(30)
HTR230(20)
Power Supply
230V AC
4 wires x 0.75 mm2
KL08NSB
KL04NSB (optional)
Actuators wires
Pump control wires
Boiler control wires
2 x 0.75 mm2
2 x 1 mm2
2 x 1 mm2
T30NC230
THB23030
PUMP (optional)
BOILER