I A - 4 Wire Installation With Kl08Nsb Wiring Centre - Salus HTRS230V(30) Full User Manual

Table of Contents

Advertisement

I A - 4 wire installation with KL08NSB wiring centre

HTRS230V(30) works mainly as a SLAVE thermostat (group thermostat) which means that it can be controlled by a MASTER thermostat e.g. HTRP230V(50).
MASTER thermostat controls SLAVE thermostat only when SLAVE thermostat is in AUTO mode. Comfort (SUN) and economy (MOON) setpoint
temperatures are set individually on each thermostat but switching between those temperature is based on time schedule taken from HTRP230(50)
thermostat which works like a group controller. Functions such as: setpoint temperature change or frost protection mode are not managed by MASTER
thermostat.
MASTER
SLAVE
e.g. HTRP230(50)
HTRS230(30) e.g. HTR230(20)
Power Supply
230V AC
4 wires x 0.75 mm2
KL08NSB
KL04NSB (optional)
Actuators wires
Pump control wires
Boiler control wires
2 x 0.75 mm2
2 x 1 mm2
2 x 1 mm2
T30NC230
THB23030
PUMP (optional)
BOILER
8