Cooling And Heating Data Sheet In Rated Frequency; Noise Curve - Gree GWH12YD-S6DBA1A Service Manual

Refrigerant: r32
Table of Contents

Advertisement

Service Manual

2.4 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°C)
(DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated heating
condition(°C)
(DB/WB)
Indoor
Outdoor
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5m.

2.5 Noise Curve

Indoor side noise
45
42
39
36
33
30
25
20
SL
L
Indoor fan motor rotating speed
Technical Information
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
12K
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
12K
ML
M
MH
H
SH
Inlet and outlet pipe
temperature of heat
exchanger
P (MPa)
T1 (°C)
0.9 to 1.1
12 to 14
Inlet and outlet pipe
temperature of heat
exchanger
P (MPa)
T1 (°C)
2.8 to 3.0
70 to 35
75
70
65
60
55
50
45
40
35
Fan speed of
indoor unit
T2 (°C)
75 to 37
Super High
Fan speed of
indoor unit
T2 (°C)
2 to 4
Super High
Outdoor side noise when blowing
20
30
40
50
Compressor frequency(Hz)
Fan speed of
outdoor unit
High
Fan speed of
outdoor unit
High
60
70
80
90
5