Gree GWH12YD-S6DBA1A Service Manual page 39

Refrigerant: r32
Table of Contents

Advertisement

Malfunction
NO.
Name
Malfunction of
phase current
43
detection
circuit for
compressor
Malfunction of
voltage
44
dropping for
DC bus-bar
Malfunction
of complete
45
units current
detection
The four-way
46
valve is
abnormal
Zero-
crossing
47
malfunction of
outdoor unit
Frequency
48
limiting
(power)
Compressor
49
running
The
temperature
50
for turning
on the unit is
reached
Frequency
limiting
51
(module
temperature)
36
Display Method of Indoor Unit
Indicator Display (during
blinking, ON 0.5s and OFF
Dual-8
0.5s)
Code
Display
Operation
Cool
Heating
Indicator
Indicator
Indicator
U1
U3
U5
U7
U9
A/C status
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling and drying
operation, compressor will stop
while indoor fan will operate;
During heating operation, the
complete unit will stop
During cooling and drying
operation, the compressor will
stop while indoor fan will
operate;
During heating operating,
the complete unit will stop
operation.
If this malfunction occurs
during
heating operation, the complete
unit will stop operation.
During cooling operation,
compressor will stop while
indoor fan will operate; during
heating,the complete unit will
stop operation.
Possible Causes
Replace outdoor control panel AP1
Supply voltage is unstable
Theres circuit malfunction on
outdoor units control panel AP1,
please replace the outdoor units
control panel AP1.
1.Supply voltage is lower than
AC175V;
2.Wiring terminal 4V is loosened or
broken;
3.4V is damaged, please replace
4V.
Replace outdoor control panel AP1
Installation and Maintenance