2.3 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling condition(°C) (DB/WB)
Indoor
Outdoor
27/19
27/19
27/19
27/19
Heating:
Rated heating condition(°C) (DB/WB)
Indoor
Outdoor
20/-
20/-
20/-
20/-
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
30
Pressure of gas pipe connecting
indoor and outdoor unit
Model
35/24
09K
35/24
12K
35/24
18K
35/24
24K
Pressure of gas pipe connecting
indoor and outdoor unit
Model
7/6
09K
7/6
12K
7/6
18K
7/6
24K
Inlet and outlet pipe temperature of
heat exchanger
P (MPa)
T1 (°C)
0.8~1.1
12 ~ 15
0.9~1.1
12 ~ 14
0.9~1.1
12 ~ 14
0.9~1.1
12 ~ 14
Inlet and outlet pipe temperature of
heat exchanger
P (MPa)
T1 (°C)
2.8~3.2
68 ~ 30
2.2~2.4
70 ~ 35
2.2~2.4
70 ~ 40
2.2~2.4
70 ~ 35
Service Manual
Fan speed of
Fan speed of
indoor unit
outdoor unit
T2 (°C)
65 ~ 38
Super High
75 ~ 37
Super High
75 ~ 37
Super High
75 ~ 37
Super High
Fan speed of
Fan speed of
indoor unit
outdoor unit
T2 (°C)
2 ~ 5
Super High
2 ~ 4
Super High
1 ~ 5
Super High
2 ~ 4
Super High
Technical Information
High
High
High
High
High
High
High
High

Hide quick links: