Cooling And Heating Data Sheet In Rated Frequency; Noise Curve - Gree GWH09QB-K6DNA5E Service Manual

Hide thumbs Also See for GWH09QB-K6DNA5E:
Table of Contents

Advertisement

2.4 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
27/19
35/24
Heating:
Rated cooling
condition(°C) (DB/WB)
Indoor
Outdoor
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.

2.5 Noise Curve

60
50
40
30
20
High
Turbo
10
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09K
0.8 ~ 1.1
12K
0.8 ~ 1.1
18K
0.9 ~ 1.1
Pressure of gas pipe
connecting indoor and
Model
outdoor unit
P (MPa)
09
2.8 ~ 3.2
12K
2.8 ~ 3.2
18K
2.2 ~ 2.4
Indoor side noise when blowing
09K
12K
Medium
Medium-high
Medium-low
Indoor fan motor rotating speed
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
12 to 15
65 to 38
11 to 14
64 to 37
12 to 14
75 to 37
Inlet and outlet pipe
temperature of heat
exchanger
T1 (°C)
T2 (°C)
35 to 63
2 to 5
35 to 65
2 to 5
70 to 35
2 to 4
56
54
52
50
18K
48
46
44
42
40
Low
Ultralow
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBo
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
TURBo
High
Outdoor side noise when blowing
18K
09/12K Heating
12K Cooling
20
30
40
50
60
Compressor frequency(Hz)
Technical Information
Service Manual
Compressor
revolution
(rps)
49
60
52
Compressor
revolution
(rps)
59
67
65
70
80
90

Advertisement

Table of Contents
loading

Table of Contents