Service Manual
2.3 Cooling and Heating Data Sheet in Rated Frequency
Cooling:
Rated cooling condition(°C)
(DB/WB)
Indoor
Outdoor
27/19
35/24
27/19
35/24
27/19
35/24
27/19
35/24
27/19
35/24
Heating:
Rated cooling condition(°C)
(DB/WB)
Indoor
Outdoor
20/-
7/6
20/-
7/6
20/-
7/6
20/-
7/6
20/-
7/6
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Technical Information
Pressure of gas pipe connecting
indoor and outdoor unit
Model
P (MPa)
07K
0.8 to 1.0
12K
0.8 to 1.1
18K
0.8 to 1.0
24K
0.9 to 1.1
28/36K
0.9 to 1.1
Pressure of gas pipe connecting
indoor and outdoor unit
Model
P (MPa)
07K
2.4 to 2.6
12K
2.4 to 2.6
18K
2.2 to 2.4
24K
2.2 to 2.4
28/36K
2.8 to 3.0
Inlet and outlet pipe temperature of
heat exchanger
T1 (°C)
T2 (°C)
in:8~11
in:75~85
out:11~14
out:37~43
in:10~14
in:69~74
out:11~14
out:38~45
in:8~11
in:75~85
out:11~14
out:37~43
in:8~12
in:75~85
out:11~14
out:37~43
in:6~8
in:75~85
out:10~12
out:37~43
Inlet and outlet pipe temperature of
heat exchanger
T1 (°C)
T2 (°C)
in:55~65
in:1~3
out:30~37
out:2~5
in:55~65
in:1~3
out:25~32
out:2~5
in:75~85
in:1~3
out:37~43
out:2~5
in:70~85
in:1~3
out:37~43
out:2~5
in:70~85
in:1~3
out:37~43
out:2~5
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
Super High
High
Super High
High
Super High
High
Super High
High
Fan speed of
Fan speed of
indoor unit
outdoor unit
Super High
High
Super High
High
Super High
High
Super High
High
Super High
High
23