Gree GWH12YD-S6DBA1A Service Manual

Gree GWH12YD-S6DBA1A Service Manual

Refrigerant: r32

Advertisement

Change for life
Service Manual
Models: GWH12YD-S6DBA1A
GWH12YD-S6DBA2A
(Refrigerant
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI
R32)
:

Advertisement

Table of Contents
loading

Summary of Contents for Gree GWH12YD-S6DBA1A

  • Page 1 Change for life Service Manual Models: GWH12YD-S6DBA1A GWH12YD-S6DBA2A (Refrigerant R32) GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI...
  • Page 2: Table Of Contents

    5.2 PCB Printed Diagram ..................... 11 6. Function and Control ..................13 6.1 Remote Controller Introduction ..................13 6.2 GREE+ App Operation Manual ..................18 6.3 Ewpe Smart App Operation Manual ................19 Part Ⅱ : Installation and Maintenance ..........20 7. Notes for Installation and Maintenance ..........20...
  • Page 3 Service Manual 9. Maintenance ......................31 9.1 Error Code List .......................31 9.2 Procedure of Troubleshooting ..................38 9.3 Maintenance Method for Normal Malfunction ..............52 10. Exploded View and Parts List ..............54 10.1 Indoor Unit ........................54 10.2 Outdoor Unit .........................56 11. Removal Procedure ..................58 11.1 Removal Procedure of Indoor Unit ................58 11.2 Removal Procedure of Outdoor Unit ................63...
  • Page 4: Part Ⅰ : Technical Information

    Part Ⅰ : Technical Information 1. Summary Indoor Unit: GWH12YD-S6DBA1A/I GWH12YD-S6DBA2A/I Outdoor Unit: GWH12YD-S6DBA2A/O Remote Controller: YAG1FB3(WiFi) Model List: Model Product code Indoor model Indoor product code Outdoor model Outdoor product code GWH12YD-S6DBA1A CB437003001 GWH12YD-S6DBA1A/I CB437N03001 GWH12YD-S6DBA2A/O CB466W00200 GWH12YD-S6DBA2A CB466000204 GWH12YD-S6DBA2A/I CB466N00204 Technical Information...
  • Page 5: Specifications

    Service Manual 2. Specifications 2.1 Specification Sheet GWH12YD-S6DBA1A Model GWH12YD-S6DBA2A CB437003001 Product Code CB466000204 Rated Voltage 220-240 Power Rated Frequency 50/60 Supply Phases Power Supply Mode Outdoor Cooling Capacity 3530 Heating Capacity 4200 Cooling Power Input Heating Power Input Cooling Power Current 5.10...
  • Page 6 Service Manual Model of Outdoor Unit GWH12YD-S6DBA2A/O Outdoor Unit Product Code CB466W00200 Compressor Manufacturer/Trademark ZHUHAI LANDA COMPRESSOR CO., LTD Compressor Model QXFT-B123zE170A Compressor Oil FW68DA/equivalent Compressor Type Rotary L.R.A. Compressor RLA Compressor Power Input 1230 Overload Protector Throttling Method Electron expansion valve Operation Temp 8~30 Ambient Temp (Cooling)
  • Page 7: Operation Characteristic Curve

    Service Manual 2.2 Operation Characteristic Curve Cooling Heating Cooling Heating Condition Condition Indoor:DB 20°C Indoor:DB27°C WB19°C Indoor air flow: Super High Indoor air flow: Super High Pipe length:5m Pipe length:5m Compressor Frequency(Hz) Compressor Frequency(Hz) 2.3 Capacity Variation Ratio According to Temperature Cooling Heating Condition...
  • Page 8: Cooling And Heating Data Sheet In Rated Frequency

    Service Manual 2.4 Cooling and Heating Data Sheet in Rated Frequency Cooling: Rated cooling Pressure of gas pipe Inlet and outlet pipe condition(°C) connecting indoor and temperature of heat Fan speed of Fan speed of Model (DB/WB) outdoor unit exchanger indoor unit outdoor unit Indoor...
  • Page 9: Outline Dimension Diagram

    Service Manual 3. Outline Dimension Diagram 3.1 Indoor Unit Φ55 Φ55 Unit:mm Model Technical Information...
  • Page 10: Outdoor Unit

    Service Manual 3.2 Outdoor Unit Unit:mm Technical Information...
  • Page 11: Refrigerant System Diagram

    Service Manual 4. Refrigerant System Diagram INDOOR UNIT OUTDOOR UNIT GAS SIDE 3-WAY VALVE 4-Way valve Discharge HEAT EXCHANGE (EVAPORATOR) Accumlator Suction COMPRESSOR HEAT EXCHANGE (CONDENSER) Intercooler LIQUID SIDE Electron Strainer Strainer Strainer Capillary Strainer 2-WAY VALVE expansion valve COOLING HEATING Connection pipe specification: Liquid pipe:1/4"...
  • Page 12: Electrical Part

    Service Manual 5. Electrical Part 5.1 Wiring Diagram ●Instruction Symbol Symbol Color Symbol Symbol Color Symbol Name White Green Jumper cap Yellow Brown COMP Compressor Blue Grounding wire YEGN Yellow/Green Black Note: Jumper cap is used to determine fan speed and the swing angle of horizontal lover for this model. ●...
  • Page 13 Service Manual ● Outdoor Unit 60000700051401 These wiring diagrams are subject to change without notice; please refer to the one supplied with the unit. Technical Information...
  • Page 14: Pcb Printed Diagram

    Service Manual 5.2 PCB Printed Diagram ● Indoor Unit Top view Name Neutral wire Needle stand for indoor fan Door control interface up&down swing motor left&right swing motor Interface of temperature sensor Terminal for display board connection Terminal of jumper cap Communication wire 10 Detecting plate(WIFI ) 11 Grounding wire...
  • Page 15 Service Manual ● Outdoor Unit Top view Name 4 5 6 8 9 10 Terminal of compressor Overload Terminal of compressor Terminal of temperature sensor Terminal of electronic expansion valve 1 Terminal of electronic expansion valve 2 Low-temperature cooling sensor Terminal of outdoor fan Terminal of chassis electric heater...
  • Page 16: Function And Control

    Service Manual 6. Function and Control 6.1 Remote Controller Introduction ON/OFF button FAN button MODE button +/- button TURBO button button button CLOCK button TIMER ON/ WiFi TIMER OFF button TEMP button button (before opening cover (after opening cover I FEEL button ON/OFF button LIGHT button FAN button...
  • Page 17 Service Manual ATUO Low fan Medium-low fan Medium fan Medium-high fan High fan Note: It’s Low fan speed under Dry mode. X-FAN function:Hold fan speed button for 2s in COOL or DRY mode, the icon “ ” is displayed and the indoor fan will continue operation for a few minutes in order to dry the indoor unit even though you have turned off the unit.
  • Page 18 Service Manual Note: Outdoor temperature display is not available for some models. At that time, indoor unit receives " " signal, while it displays indoor set temperature. Press this button once, to turn on the I FEEL function, then the figure of "I FEEL"will be displayed, after every press of other function button, every 200ms to sendI FEEL once, after this function started, the remote controller will send temperatureto the main un it in every 10 minutes.
  • Page 19 Service Manual (4) When setting the initial temperature 30℃, under this temperature setting, after 7hours, the temperature will be decreased 1℃, after that the unit will keep onrunning under this temperature; In Heat mode: (1) Under the initial presetting temperature 16℃, it will run under this setting temperature all along. (2) Under the initial presetting temperature17℃-20℃, after Sleep function started up, the temperature will decrease 1℃...
  • Page 20 Service Manual 1. After powered on, press ON/OFF button, the unit will start to run. (Note: When it is powered on, the guide louver of main unit will close automatically.) 2. Press MODE button, select desired running mode. WiFi 3. Pressing + or - button, to set the desired temperature. 4.
  • Page 21: Gree+ App Operation Manual

    GREE+ App Download Linkage Scan the QR code or search "GREE+" in the application market to download and install it. When "GREE+" App is installed, register the account and add the device to achieve long-distance control and LAN control of Gree smart home appliances.
  • Page 22: Ewpe Smart App Operation Manual

    Service Manual 6.3 Ewpe Smart App Operation Manual Control Flow Chart Internet Cloud intelligent Cellular/ Home Wi-Fi home Other Wi-FI appliances Home wireless router Home Wi-Fi Operating Systems Requirement for User's smart phone: iOS system Android system Support iOS7.0 and Support Android 4.4 and above version above version...
  • Page 23: Part Ⅱ : Installation And Maintenance

    Service Manual Part Ⅱ : Installation and Maintenance 7. Notes for Installation and Maintenance Safety Precautions: 10. If the power cord or connection wire is not long enough, please get the specialized power cord or connection wire Important! from the manufacture or distributor. Prohibit prolong the wire by yourself.
  • Page 24 Service Manual Safety Precautions for Installing and Relocating the Unit: To ensure safety, please be mindful of the following precautions. Warnings 1. When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the specified refrigerant.
  • Page 25 Service Manual Safety Operation of Flammable Refrigerant Qualification requirement for installation and maintenance man ●All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using the flammable refrigerant.
  • Page 26 Service Manual Main Tools for Installation and Maintenance 1. Level meter, measuring tape 2. Screw driver 3. Impact drill, drill head, electric drill 4. Electroprobe 5. Universal meter 6. Torque wrench, open-end wrench, inner hexagon spanner 7. Electronic leakage detector 8.
  • Page 27: Installation

    Service Manual 8. Installation 8.1 Installation Dimension Diagram Space to the wall Space to the wall At least 5 7/8 At least 5 7/8 Drainage pipe Installation and Maintenance...
  • Page 28 Service Manual Installation procedures Start installation Preparation before installation Read the requirements select installation Prepare tools for electric connection location Select indoor unit Select outdoor unit installation location installation location Install the support of outdoor unit Install wall-mounting (select it according to the actual situation) frame, drill wall holes Connect pipes of indoor Fix outdoor unit...
  • Page 29: Installation Parts-Checking

    Service Manual 8.2 Installation Parts-checking 8.4 Electric Connection Requirement 1. Safety Precaution Name Name (1) Must follow the electric safety regulations when installing Indoor unit Sealing gum the unit. Outdoor unit Wrapping tape (2) According to the local safety regulations, use qualified Support of outdoor power supply circuit and air switch.
  • Page 30 Service Manual in the holes. 5. Connect the Pipe of Indoor Unit (3) Fix the wall-mounting frame on the wall with tapping screws (1) Aim the pipe joint at the corresponding bellmouth.(As show (ST4.2X25TA) and then check if the frame is firmly installed by in Fig.5) pulling the frame.
  • Page 31 Service Manual 7. Connect Wire of Indoor Unit 8. Bind up Pipe (1) Open the panel, remove the screw on the wiring cover and (1) Bind up the connection pipe, power cord and drain hose then take down the cover.(As show in Fig.11) with the band.(As show in Fig.14) (2) Reserve a certain length of drain hose and power cord Screw...
  • Page 32: Installation Of Outdoor Unit

    Service Manual 8.6 Installation of Outdoor Unit (3) Pretightening the union nut with hand. (4) Tighten the union nut with torque wrench . 1. Fix the Support of Outdoor Unit(Select it according to Refer to the following table for wrench moment of force: the actual installation situation) (1) Select installation location according to the house structure.
  • Page 33: Vacuum Pumping And Leak Detection

    Service Manual Note: 2. Leakage Detection (1) With leakage detector: (1) The through-wall height of drain hose shouldnt be higher Check if there is leakage with leakage detector. than the outlet pipe hole of indoor unit.(As show in Fig.25) (2) With soap water: (2) Slant the drain hose slightly downwards.
  • Page 34: Maintenance

    Service Manual 9. Maintenance 9.1 Error Code List Display Method of Indoor Unit Indicator Display (during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes Name 0.5s) Code Display Operation Cool Heating Indicator Indicator Indicator During cooling and drying Possible reasons: High operation, except indoor...
  • Page 35 Service Manual Display Method of Indoor Unit Indicator Display (during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes Name 0.5s) Code Display Operation Cool Heating Indicator Indicator Indicator When the outdoor unit receive signal of Gathering refrigerant Gathering ,the system will be forced to Nominal cooling mode...
  • Page 36 Service Manual Display Method of Indoor Unit Indicator Display (during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes Name 0.5s) Code Display Operation Cool Heating Indicator Indicator Indicator Decrease Overload or temperature is too All loads operate normally, frequency high;...
  • Page 37 Service Manual Display Method of Indoor Unit Indicator Display (during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes Name 0.5s) Code Display Operation Cool Heating Indicator Indicator Indicator Compressor intermediate Showing during middle cooling or frequence in middle heating test test state During cooling and drying...
  • Page 38 Service Manual Display Method of Indoor Unit Indicator Display (during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes Name 0.5s) Code Display Operation Cool Heating Indicator Indicator Indicator During cooling and drying operation, compressor will stop Refer to the malfunction analysis System is while indoor fan will operate;...
  • Page 39 Service Manual Display Method of Indoor Unit Indicator Display (during Malfunction blinking, ON 0.5s and OFF Dual-8 A/C status Possible Causes Name 0.5s) Code Display Operation Cool Heating Indicator Indicator Indicator Malfunction of During cooling and drying phase current operation, compressor will stop detection while indoor fan will operate;...
  • Page 40 Service Manual Display Method of Indoor Unit Indicator Display (during blinking, ON 0.5s and OFF Dual-8 Malfunction A/C status Possible Causes 0.5s) Code Name Operation Cool Heating Display Indicator Indicator Indicator Normal communica- tion OFF 3S Defrosting will occur in and blink heating once...
  • Page 41: Procedure Of Troubleshooting

    Service Manual 9.2 Procedure of Troubleshooting 1. Malfunction of Temperature Sensor F1, F2 Main detection points: ● Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted? ● Is there short circuit due to trip-over of the parts? ●...
  • Page 42 Service Manual 2. Malfunction of Blocked Protection of IDU Fan Motor H6 Main detection points: ● SmoothlyIs the control terminal of PG motor connected tightly? ● SmoothlyIs the feedback interface of PG motor connected tightly? ● The fan motor cant operate? ●...
  • Page 43 Service Manual 3. Malfunction of Protection of Jumper Cap C5 Main detection points: ● Is there jumper cap on the mainboard? ● Is the jumper cap inserted correctly and tightly? ● The jumper is broken? ● The motor is broken? ●...
  • Page 44 Service Manual 4. Malfunction of Overcurrent Protection E5 Main detection points: ● Is the supply voltage unstable with big fluctuation? ● Is the supply voltage too low with overload? ● Hardware trouble? Malfunction diagnosis process: Start Normal fluctuation should be within 10 % Is malfunction Is the supply voltage unstable of the rated voltage on the nameplate...
  • Page 45 Service Manual 5. Communication Malfunction E6 Start Cut off power supply. Check if connection line of IDU and ODU and the wire inside electric box are correctly connected. Connect the line Correct connection? according to Malfunction eliminated? wiring diagram. Main board matches Match correctly with display board? Main board of Malfunction eliminated?
  • Page 46 Service Manual 6. Malfunction of Zero-crossing Inspection Circuit Malfunction of the IDU Fan Motor U8 Main detection points: ● Instant energization afte de-energization while the capacitordischarges slowly? ● The zero-cross detectioncircuit of the mainboard is defined abnormal? Malfunction diagnosis process: Start Turn power off for 1minute,the turn...
  • Page 47 Service Manual 7. Malfunction of detecting plate(WIFI) JF 5. Malfunction of detecting plate(WIFI) JF Start check if the connection wire are correctly connected detecting Replace the plate with the same model Is malfunction eliminated Replace the mainboard with the same model The end Installation and Maintenance...
  • Page 48 Service Manual Outdoor Unit 1. Capacity charging malfunction (outdoor unit malfunction) (AP1 below means control board of outdoor unit) Main detection points: ● Detect if the voltage of L and N terminal of XT wiring board is between 210VAC-240VAC by alternating voltage meter; ●...
  • Page 49 Service Manual 5. IPM protection, phase current overcurrent (the control board as below indicates the control board of outdoor unit) H5/P5 Mainly detect: (1) Compressor COMP terminal (2) voltage of power supply (3) compressor (4) Refrigerant-charging volume (5) air outlet and air inlet of outdoor/indoor unit Troubleshooting: Turn on the unit after energization...
  • Page 50 Service Manual 3. High temperature and overload protection (E8)(AP1 below means control board of outdoor unit) Main detection points: ● If the outdoor ambient temperature is in normal range; ● If the indoor and outdoor fan are running normally; ● If the radiating environment of indoor and outdoor unit is good. E8 is displayed Normal protection, please If the outdoor...
  • Page 51 Service Manual 4. Start-up failure (LC) (AP1 below means control board of outdoor unit) Main detection points: ● If the compressor wiring is correct? ● If the stop time of compressor is sufficient? ● If the compressor is damaged? ● If the refrigerant charging amount is too much? Turn on the unit The stop time is not sufficient and If the stop time of compressor...
  • Page 52 Service Manual 5. Overload and high discharge temperature malfunction Main detection points: ● If the electronic expansion valve is connected well? Is the electronic expansion valve damaged? ● If the refrigerant is leaked? ● The compressor overload protection terminal is not connected well with the mainboard? ●...
  • Page 53 Service Manual H3 or E4 is displayed 30min after power off the unit If the overload protector SAT is well connected? Under ambient temperature, test the resistance of overload protector with ohmmeter; resistance value should be<1000ohm Connect wire If the wiring terminal FA of electronic according to wiring expansion valve is well connected? diagram...
  • Page 54 Service Manual 6. Communication malfunction (E6) Main detection points: ● Check if the connection wire and the built-in wiring of indoor and outdoor unit are connected well and without damage; ● If the communication circuit of indoor mainboard is damaged? If the communication circuit of outdoor mainboard (AP1) is damaged? Malfunction diagnosis process: If the unit operates normally before malfunction...
  • Page 55: Maintenance Method For Normal Malfunction

    Service Manual 9.3 Maintenance Method for Normal Malfunction 1. Air Conditioner Cant be Started Up Possible Causes Discriminating Method (Air conditioner Status) Troubleshooting Confirm whether its due to power failure. If yes, No power supply, or poor After energization, operation indicator isnt bright wait for power recovery.
  • Page 56 Service Manual 4. ODU Fan Motor Cant Operate Possible causes Discriminating method (air conditioner status) Troubleshooting Connect wires according to wiring diagram to Wrong wire connection, or poor Check the wiring status according to circuit make sure all wiring terminals are connected connection diagram firmly...
  • Page 57: Exploded View And Parts List

    Service Manual 10. Exploded View and Parts List 10.1 Indoor Unit The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
  • Page 58 Service Manual Part Code Description GWH12YD-S6DBA2A/I GWH12YD-S6DBA1A/I Product Code CB466N00204 CB437N03001 Front Panel Assy 20000300057 200003000050 Filter Sub-Assy 1112208906 1112208906 Screw Cover 2425201726 2425201726 Front Case Assy 00000200060 00000200060 Air Louver(Manual) 10512733 10512733 Flail(Gray) 10512731 10512731 Helicoid Tongue 26112512 26112512...
  • Page 59: Outdoor Unit

    Service Manual 10.2 Outdoor Unit The component picture is only for reference; please refer to the actual product. Installation and Maintenance...
  • Page 60 Service Manual Part Code Description GWH12YD-S6DBA2A/O Product Code CB466W00200 Front Grill 22413046 Cabinet 01433034P Axial Flow Fan 10333011 Brushless DC Motor 1501308511 Clapboard Sub-Assy 01235094 Left Side Plate 01303169P Valve Cover 22243005 Main Board 300027000056 Electric Box Assy 100002000997 Coping 01253034P Rear Grill 01475022...
  • Page 61: Removal Procedure

    Service Manual 11. Removal Procedure Caution: discharge the refrigerant completely before removal. 11.1 Removal Procedure of Indoor Unit Step Procedure Panel Open the panel. Loosen the clasp shown and outwards to remove them. 2.Remove horizontal louver Push out the axile bush on horizontal louver.
  • Page 62 Service Manual Step Procedure 3.Remove display and panel Screws Screws that are locking the display board. Display Separate the display board from the front Panel panel. Open the front panel; separate the panel front panel and then removes the front panel.
  • Page 63 Service Manual Step Procedure 7.Remove cold plasma generator Cold plasma generator Screws that are locking the cold plasma Screw generator.Separate the display board from the evaporator assy. 8.Remove temperature sensor and grounding wire Grounding wire Temperature sensor Cut off the tieline which binding the temperature sensor and grounding wire on the evaporator, and then pull out the indoor tube temperature sensor from the...
  • Page 64 Service Manual Step Procedure 11.Electric box assy assy and then remove the electric box assy. Electric box assy Screw 12.Remove connection pipe clamp Screw Connection pipe clamp At the back of the unit, remove the and then remove the connection pipe clamp.
  • Page 65 Service Manual Step Procedure Motor clamp Screws and then remove the motor clamp. Remove the screws at the connection to remove them. Motor Screw Remove the bearing holder sub-assy. Holder sub-assy Installation and Maintenance...
  • Page 66: Removal Procedure Of Outdoor Unit

    Service Manual 11.2 Removal Procedure of Outdoor Unit 1. Before disassembly 2. Remove top cover Remove the screws connecting top cover, left and right side plate, as well as panel, to remove the top top cover cover. Remove handle and valve cover Twist off the screws used for fixing the handle and valve cover, pull the handle and valve cover up ward to remove it.
  • Page 67 Service Manual Remove panel and grille Remove the screws fixing panel, to remove the panel. Remove the screws connecting panel grille and panel, loosen the clamp, to remove the panel grille. panel grille Remove cross fan blade Remove the screw nut fixing cross fan blade, remove the gasket and spring cushion, to remove the cross fan blade.
  • Page 68 Service Manual Remove motor Remove the four tapping screws fixing motor, pull out the contact tag of motor wiring, to remove the motor. motor Remove motor support Remove the two tapping screws fixing motor support and chassis, lift to remove the motor support. motor suppor 8.
  • Page 69 Service Manual 9. Remove electric box assy electric box cover Remove screws fixing electric box assy and mid-isolation board, loosen the bonding tie, pull off the wiring terminal, lift to remove the electric box assy. electric box assy Remove four-way valve assy four-way valve ass Welding cut the spot weld of four-way valve assy, compressor air suction/discharging valve and...
  • Page 70 Service Manual 12. Remove compressor compressor Remove the three feet screw nuts fixing compresso to remove the compressor. 13. Remove big and smal l valve assy Remove screws connecting condenser assy and chassis, to remove the condenser assy. Remove the screws fixing big and small valve, to remove the valves.
  • Page 71: Appendix

    Service Manual Appendix: Appendix 1: Reference Sheet of Celsius and Fahrenheit Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32 Set temperature Fahrenheit Fahrenheit Fahrenheit display Fahrenheit display Fahrenheit display Fahrenheit Celsius(°C) Celsius(°C) Celsius(°C) temperature (°F) temperature (°F) temperature (°F) (°F) (°F) (°F)
  • Page 72: Appendix 3: Pipe Expanding Method

    Service Manual Appendix 3: Pipe Expanding Method Pipe Note: Pipe cutter Improper pipe expanding is the main cause of refrigerant leakage.Please expand the pipe according to the following steps: Leaning Uneven Burr A:Cut the pip ● Confirm the pipe length according to the distance of indoor unit and outdoor unit. ●...
  • Page 73: Appendix 4: List Of Resistance For Temperature Sensor

    Service Manual Appendix 4: List of Resistance for Temperature Sensor Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor (15K) Temp( C) Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( Resistance(kΩ) 138.1 18.75 3.848 1.071 128.6 17.93 3.711 1.039 121.6 17.14 3.579 1.009...
  • Page 74 Service Manual Resistance Table of Tube Temperature Sensors for Indoor and Outdoor (20K) Temp( C) Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( Resistance(kΩ) 181.4 25.01 5.13 1.427 171.4 23.9 4.948 1.386 162.1 22.85 4.773 1.346 153.3 21.85 4.605 1.307 20.9 4.443 1.269 137.2...
  • Page 75 Service Manual Resistance Table of Discharge Temperature Sensor for Outdoor (50K) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) Temp( C) Resistance(kΩ) Temp( Resistance(kΩ) 853.5 18.34 4.75 799.8 93.42 17.65 4.61 89.07 16.99 4.47 703.8 84.95 16.36 4.33 660.8 81.05 15.75 4.20 620.8 77.35 15.17 4.08...
  • Page 76 Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com HONG KONG GREE ELECTRIC APPLIANCES SALES LIMITED Add: Unit 2612,26/F.,Miramar Tower 132 Nathan Road,TST,Kowloon,HK Tel: (852) 31658898 Fax: (852) 31651029 For product improvement, specifications and appearance in this manual are subject to change without prior notice.

This manual is also suitable for:

Gwh12yd-s6dba2a