Service Manual 2.4 Cooling and Heating Data Sheet in Rated Frequency Cooling: Rated cooling Compressor condition(°C) connecting indoor and Model (DB/WB) (Hz) Indoor P (MPa) T1 (°C) T2 (°C) 27/19 35/24 0.9 to 1.1 12 to 14 75 to 37 Heating: Compressor condition(°C)
Service Manual 4. Refrigerant System Diagram Cooling model Indoor unit Outdoor unit Gas pipe side Valve Di s charge Heat exchanger (evaporator) Suction Accumlator Compressor Heat exchanger (condenser) Liquid pipe side Valve Capillary Strainer COOLING Cooling and heating model Outdoor unit Indoor unit Gas pipe side...
Service Manual 5. Electrical Part 5.1 Wiring Diagram Symbol Symbol Color Symbol Symbol Color Symbol Name Green Yellow Brown COMP Compressor YEGN Yellow/Green Violet Orange GWC09QB-K3DNA1B/I GWH09QB-K3DNA1B/I(CB419N01700) GWH09QB-K3DNA2B/I GWC12QC-K3DNA1B/I GWH12QC-K3DNA1B/I(CB419N01900) GWH12QC-K3DNA2B/I TUBE TEMP. ROOM TEMP. RECEIVER AND FAN MOTOR SENSOR SENSOR DISPLAY BOARD DISPLAY...
Page 19
Service Manual GWC09QB-K3DNA1B/O GWC12QC-K3DNA1B/O WARNING Please don't touch any EXHAUST OUTTUBE OUTROOM terminal when the machine is TEMP. TEMP. TEMP. running ,stopping or has been SENSOR SENSOR SENSOR REACTOR powered off for less than 30 minutes to prevent the risk of electric shock ! LX1-1 LX1-2...
Page 20
Service Manual GWC18QD-K3DNA1B/O GWH18QD-K3DNA1B/O...
Service Manual 5.2 PCB Printed Diagram Indoor Unit Top view Name Interface of compressor control plasma Interface of indoor fan plasma motor Interface of indoor fan interface Interface of display Bottom view...
Page 22
Service Manual Outdoor Unit Top view 9K/12K Name Terminal of compressor wire Reactor interface 1 Reactor interface 2 Bottom view...
Page 23
Service Manual Top view Name Terminal of compressor wire protection protection sensor Terminal of electronic expansion Bottom view...
Service Manual 6. Function and Control 6.1 Remote Controller Introduction Introduction for icons on display screen Set fan speed I feel Send signal Operation mode Cool mode Dry mode Set time Heat mode Sleep mode Temp. display type :Set temp. :Indoor ambient temp.
Page 25
Service Manual 1. ON/OFF button 2. MODE button AUTO COOL HEAT Note: 3. FAN button Auto Caution: 4. SWING button no display Note: 5. TURBO button button...
Page 26
Service Manual 7. SLEEP button 8. TEMP button no display r no di Note: 9. I FEEL button 10. LIGHT button 11. CLOCK button Note: 12. TIMER ON / TIMER OFF button Note:...
Page 27
Service Manual Function introduction for combination buttons 1. Energy-saving function Note: 2. 8 heating function at 8 Note: TURBO 3. Child lock function 4. Temperature display switchover function Operation guide Replacement of batteries in remote controller signal sender battery reinstall are correct.
Service Manual 6.2 Brief Description of Modes and Functions Indoor Unit 1.Basic function of system (1)Cooling mode (2)Drying mode (3)Heating mode (4)Working method for AUTO mode: (5)Fan mode 2. Other control (1) Buzzer (2) Auto button (3) Auto fan (4) Sleep (5) Timer function: (6) Memory function (7) Health function...
Page 29
Service Manual (8)I feel control mode (9)Entry condition for compulsory defrosting function C (or 16.5 (10)Refrigerant recovery function: (11)Ambient temperature display control mode displayed. (12)Off-peak energization function: (13) SE control mode (14) X-fan mode (15) 8º heating function (16)Turbo function...
Service Manual Outdoor Unit 1. Cooling mode: start operation. Indoor fan operates according to set fan speed. Indoor fan operates according to set fan speed. 2. Drying mode 3. Fan mode 4. Heating mode 5. Freon recovery mode 6. Compulsory defrosting Installation and Maintenance...
Page 31
Service Manual 7. Auto mode 8. 8 heating . Display board of IDU displays 8 When power on, communication light will be blinking in a normal way (after receiving a group of correct signals, blinking stops for 0.2s~0.3s). If there’s no communication, communication light will be always on. If other ODU has malfunction, communication light will be on for 1s and off for 1s in a circular way.
Service Manual Part : Installation and Maintenance 7. Notes for Installation and Maintenance Safety Precautions: 10. If the power cord or connection wire is not long enough, please get the specialized power cord or connection wire Important! from the manufacture or distributor. Prohibit prolong the wire by yourself.
Page 33
Service Manual Main Tools for Installation and Maintenance 1. Level meter, measuring tape 2. Screw driver 3. Impact drill, drill head, electric drill 4. Electroprobe 5. Universal meter 6. Torque wrench, open-end wrench, inner hexagon spanner 7. Electronic leakage detector 8.
Service Manual 8. Installation 8.1 Installation Dimension Diagram Space to the wall Space to the wall At least 15cm At least 15cm Drainage pipe Installation and Maintenance...
Page 35
Service Manual Start installation Preparation before installation Read the requirements select installation Prepare tools for electric connection location Select indoor unit Select outdoor unit installation location installation location Install wall-mounting Install the support of outdoor unit (select it according to the actual situation) frame, drill wall holes Connect pipes of indoor Fix outdoor unit...
Service Manual 8.4 Electric Connection Requirement 8.2 Installation Parts-checking 1. Safety Precaution Name Name Wrapping tape Connection pipe Drainage pipe frame Connecting conditioner. cable(power cord) remote controller Wall pipe Air-conditioner 09K/12K/18K Note: 8.3 Selection of Installation Location 1. Basic Requirement: 2.
Page 37
Service Manual 4. Outlet Pipe 3. Install Wall-mounting Frame 09K: Rear left Wall Wall Level meter Mark in the middle of it Right Space Space to the to the Left Right wall wall above above 150mm 150mm Right Left Cut off Φ55mm Φ55mm the hole...
Page 38
Service Manual Note: Drain hose connected by a professional. Outlet pipe Tape Drain hose Outlet pipe Note: 8. Bind Up Pipe Drain hose Insulating pipe 7. Connect Wire of Indoor Unit Indoor and Screw outdoor power cord Panel Indoor unit pipe Liquid pipe...
Service Manual 8.6 Installation of Outdoor Unit 1. Fix the Support of Outdoor Unit(select it according to the actual installation situation) 15~20 30~40 45~55 60~65 expansion screws. 70~75 Note: 5. Connect Outdoor Electric Wire N(1) blue black brown yellow- green Indoor unit connection screws are needed.
Service Manual 2. Leakage Detection Note: 8.8 Check after Installation and Test Operation 1. Check after Installation The drain hose can't be fluctuant installation. The water outlet can't be placed The drain hose in water can't be fluctuant The water emit noise.
Service Manual 9. Maintenance 9.1 Error Code List Unit Name 0.5s) Code 0.5s Display Operation Cool Heating Yellow Green Indicator Indicator Indicator Indicator Indicator Indicator Possible reasons: operation, except indoor fan operates, all loads stop protection of operation. once system Antifreezing operation, compressor and protection...
Page 42
Service Manual Unit Name 0.5s) Code 0.5s Display Operation Cool Heating Yellow Green Indicator Indicator Indicator Indicator Indicator Indicator Nominal cooling mode refrigerant 1 times 1 times 1. Loosening or bad contact of indoor ambient temp. sensor and Indoor mainboard terminal. ambient 2.
Page 43
Service Manual Unit Name 0.5s) Code 0.5s Display Operation Cool Heating Yellow Green Indicator Indicator Indicator Indicator Indicator Indicator Decrease All loads operate normally, 9 times twice compressor is decreased Limit/ decrease All loads operate normally, speed is too low 2 times 2 times compressor is decreased...
Page 44
Service Manual Unit Name 0.5s) Code 0.5s Display Operation Cool Heating Yellow Green Indicator Indicator Indicator Indicator Indicator Indicator Compressor intermediate test state operation, compressor will stop protection of analysis (IPM protection, loss 15 times compressor operation. operation, compressor will stop 17 times of capacitor operation, compressor will stop...
Page 45
Service Manual Unit Name 0.5s) Code 0.5s Display Operation Cool Heating Yellow Green Indicator Indicator Indicator Indicator Indicator Indicator 1. Bad contact of DC motor Internal fan motor, external fan 2. Bad contact of DC motor Internal motor motor, compressor and electric control end.
Page 46
Service Manual Unit Name 0.5s) Code 0.5s Display Operation Cool Heating Yellow Green Indicator Indicator Indicator Indicator Indicator Indicator operation, compressor will stop detection 13 times compressor operation, compressor will stop dropping for 20 times of complete operate; 13 times detection control panel AP1.
Page 47
Service Manual If malfunction occurs,corresponding code will display and the unit will resume normal until protection or malfunction disappears. Installation and Maintenance...
Page 48
Service Manual Analysis or processing of some of the malfunction display: 1. Compressor discharge protection 2. Low voltage overcurrent protection 3. Communication malfunction 4. Sensor open or short circuit 5. Compressor over load protection 6. System malfunction 7. IPM module protection Installation and Maintenance...
Page 49
Service Manual 9.2 Procedure of Troubleshooting Indoor unit 1. Malfunction of Temperature Sensor F1, F2 Troubleshooting for F1,F2 malfunction the wiring terminal between the temperature sensor and the controller loosened or poorly contacted? Insert the temperature sensor tightly Is malfunction eliminated Is there short circuit due to trip - over of the parts?
Page 50
Service Manual 2. Malfunction of Blocked Protection of IDU Fan Motor H6 Troubleshooting for H6 malfunction Stir the blade with a tool to see whether the blade rotates smoothly Tighten the screw; reassemble the blade, motor and shaft bearing rubber base sub-assy to make sure there is no foreign object between them Is malfunction eliminated...
Page 51
Service Manual 3. Malfunction of Protection of Jumper Cap C5 Troubleshooting for C5 malfunction Appearance of Is there jumper cap on the the jumper cap mainboard ? Assemble the jumper cap with the same model Is malfunction eliminated the jumper cap inserted correctly and tightly ? Insert the...
Page 52
Service Manual 6. Malfunction of Zero-crossing Inspection Circuit Malfunction of the IDU Fan Motor U8 Troubleshooting for U8 malfunction Re-energize1 minute after de-erergization The unit returns to normal. Conclusion:U8 is displayed due U8 is still to instant energization afte de- displayed energization while the capacitor discharges slowly.
Page 53
Service Manual Outdoor unit 1. Capacitor charge fault (Fault with outdoor unit) (AP1 below refers to the outdoor control panel) Turn on the unit and wait 1 minute Use DC voltmeter to measure the voltage on the two ends of electrolytic capacitor Fault with the voltage Replace the control...
Page 54
Service Manual 2. IPM Protection, Out-of-step Fault, Compressor Phase Overcurrent (AP1 below refers to the outdoor control panel) Installation and Maintenance...
Page 55
Service Manual Energize and switch on Use AC voltmeter If the voltage Check the supply to measure the IPM protection between terminal L voltage and voltage between occurs after the and N on wiring machine has run for terminal L and N restore it to board XT is within a period of time?
Page 56
Service Manual 3. High temperature and overload protection diagnosis (AP1 hereinafter refers to the control board of the outdoor unit) Mainly detect: Overheat and high temperature protection Normal protection, please operate it after the outdoor ambient temp- Is outdoor ambient temperature higher than 53? erature is normalized.
Page 57
Service Manual 4. Start-up failure (following AP1 for outdoor unit control board) Mainly detect: Power on the unit Restart it up after Is stop time of the compressor 3 minutes longer than 3 minutes? Does startup fail? Connect the wires as Are the wires for the compressor connected per the connection correctly? Is connection sequence right?
Page 58
Service Manual 5. Out of step diagnosis for the compressor (AP1 hereinafter refers to the control board of the outdoor unit) Mainly detect: Out of step occurs in Out of step occurs once the operation unit is powered on. Check if the fan terminal Is stop time of the Replace the fan Is the outdoor fan working...
Page 59
Service Manual 6. Overload and air exhaust malfunction diagnosis (following AP1 for outdoor unit control board) Mainly detect: 20 minutes after the complete unit is powered off Is the terminal FA for the Connect the electronic expansion valve wires correctly connected correctly? Resistances between the first four pins close to the terminal hole and the fifth...
Page 60
Service Manual 7. Power factor correct or (PFC) fault (a fault of outdoor unit) (AP1 hereinafter refers to the control board of the outdoor unit) Mainly detect: Start Check wiring of the reactor (L) of the outdoor unit and the PFC capacitor Replace it as per the Whether there is any...
Page 61
Service Manual 8. Communication malfunction: (following AP1 for outdoor unit control board) Mainly detect: Start Did the equipment operate normally before the failure occurs? Check the wiring of the indoor and outdoor units with reference to the wiring diagram Check wiring inside of the indoor and outdoor Is the connection right? units...
Service Manual 9.3 Troubleshooting for Normal Malfunction 1. Air Conditioner Can't be Started Up connected well. Wrong wire connection between or poor connection for wiring terminals reliably correctly once improper Replace batteries for remote controller Repair or replace remote controller 2.
Page 63
Service Manual 4. ODU Fan Motor Can't Operate Connect wires according to wiring diagram to Wrong wire connection, or poor connection diagram damaged fan capacitor. is bad and ODU compressor generates a lot of 5. Compressor Can't Operate Connect wires according to wiring diagram to Wrong wire connection, or poor connection diagram...
Service Manual 10. Exploded View and Parts List 10.1 Indoor Unit GWC09QB-K3DNA1B/I GWH09QB-K3DNA1B/I GWH09QB-K3DNA2B/I GWH09QB-K3DNA5B/I GWH09QB-K3DNA6B/I Installation and Maintenance...
Service Manual 11. Removal Procedure 11.1 Removal Procedure of Indoor Unit Step Procedure case Location of step motor A1/A5 display Screws Panel panel. step 5 of disassembly). A2/A6 display Panel rotation Screws B2 display Screws Installation and Maintenance...
Page 88
Service Manual Step Procedure Screw Screws Note: Screw caps models. Screw Clasp Bottom case Vertical Vertical Clasps Installation and Maintenance...
Page 89
Service Manual Step Procedure Clasps Electric box Electric box assy sensor generator. Cold plasma generator sensor. Wiring terminal Screw stepping motor. of motor Wiring Water retaining terminal of stepping motor Screw Main board box assy. Power cord Screw Wire clip Installation and Maintenance...
Page 90
Service Manual Step Procedure circlip terminals. connector terminal. Screws Connection pipe clamp Screw Bottom case Clasp Connection pipe Installation and Maintenance...
Page 91
Service Manual Step Procedure Screws Motor clamp Screw Motor place of cross flow blade and motor; lift Holder Screws Step motor Installation and Maintenance...
Service Manual 11.2 Removal Procedure of Outdoor Unit 9K/12K Step Procedure Screw Screws Top panel Screw Screws grille Screws Installation and Maintenance...
Page 93
Service Manual Step Procedure Screws Screws Screws Screws Installation and Maintenance...
Page 94
Service Manual Step Procedure Screws Screws Left side plate Screws Screws Screws Electric box assy Note: Installation and Maintenance...
Page 95
Service Manual Step Procedure Spot weld Note: Motor Screws Screws Installation and Maintenance...
Page 96
Service Manual Step Procedure Screws Screws Clapboard Screws Screws Installation and Maintenance...
Page 97
Service Manual Step Procedure Note: Compressor Condenser Screw Screw Installation and Maintenance...
Page 98
Service Manual Step Procedure Screw Screw Screw Top panel Screw front grille. Screw Installation and Maintenance...
Page 99
Service Manual Step Procedure Cabinet Screw Screw Screw grille. Screw Rear grill Screw Installation and Maintenance...
Page 100
Service Manual Step Procedure Left side plate Screw Screw Electric box assy Note: Installation and Maintenance...
Page 101
Service Manual Step Procedure Screw Motor Screw Note: Spot weld Installation and Maintenance...
Page 102
Service Manual Step Procedure Note: enter it. Compressor Screw Clapboard Screw Installation and Maintenance...
Page 103
Service Manual Step Procedure Condenser Screw Installation and Maintenance...
Service Manual Appendix 3: Pipe Expanding Method Pipe Note: Pipe cutter Improper pipe expanding is the main cause of refrigerant leakage.Please expand the pipe according to the following steps: Leaning Uneven Burr Pipe Shaper Downwards Union pipe Pipe Hard mold Note: Expander A(mm)
Page 106
Service Manual Appendix 4: List of Resistance for Temperature Sensor Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units(15K) Temp( Temp( Temp( Temp( 138.1 18.75 3.848 1.071 128.6 17.93 3.711 1.039 121.6 17.14 3.579 1.009 16.39 3.454 0.98 108.7 15.68 3.333...
Page 107
Service Manual Resistance Table of Tube Temperature Sensors for Outdoor and Indoor(20K) Temp( Temp( Temp( Temp( 181.4 25.01 5.13 1.427 171.4 23.9 4.948 1.386 162.1 22.85 4.773 1.346 153.3 21.85 4.605 1.307 20.9 4.443 1.269 137.2 4.289 1.233 129.9 19.14 4.14 1.198 18.13...