Capacity Variation Ratio According To Temperature; Cooling And Heating Data Sheet In Rated Frequency - Gree GVC24AMXF-K3NTC7A Service Manual

Table of Contents

Advertisement

2. Specifications

2.2 Capacity Variation Ratio According to Temperature

Cooling:
140
120
100
80
60
40
20
0
15
18
20
25

2.3 Cooling and Heating Data Sheet in Rated Frequency

Cooling:
Rated cooling condition(°C) (DB/WB)
Indoor
Outdoor
27/19
Heating:
Rated cooling condition(°C) (DB/WB)
Indoor
Outdoor
20/-
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
10
Condition Cooling
Indoor: DB27°C WB19°C
Indoor air flow: Super High
Pipe length: 5m
30
35
40
45
Outdoor temp.(°C)
Pressure of gas pipe connecting
indoor and outdoor unit
Model
35/24
24K / 36K
Pressure of gas pipe connecting
indoor and outdoor unit
Model
7/6
24K / 36K
Heating:
140
120
100
80
60
40
20
0
50
52
55
-10
-7
Inlet and outlet pipe temperature of
P (MPa)
T1 (°C)
in: 9
0.4 ~ 0.6
out: 12
Inlet and outlet pipe temperature of
P (MPa)
T1 (°C)
in: 80
1.6 ~ 1.8
out: 35
Condition Heating
Indoor: DB20°C
Indoor air flow: Super High
Pipe length: 5m
-5
0
5
10
Outdoor temp.(°C)
heat exchanger
Fan speed of
indoor unit
T2 (°C)
in: 80
Super High
out: 36
heat exchanger
Fan speed of
indoor unit
T2 (°C)
in: 2
Super High
out: 4
Technical Information
Service Manual
15
20
24
25
Fan speed of
outdoor unit
High
Fan speed of
outdoor unit
High

Advertisement

Table of Contents
loading

Table of Contents