6.1.9 Other Approvals; Emc And Environmental Type Tests - Siemens SIMATIC NET RUGGEDCOM RS950G Installation Manual

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS950G:
Table of Contents

Advertisement

Certification
6.1.9 Other Approvals
6.1.9
Other Approvals
This device meets the requirements of the following additional standards:
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS950G has passed the following EMC and environmental tests.
IEC 61850-3 Type Tests
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
28
IEEE 1613
IEEE Standard Environmental and Testing Requirements for Communications
Networking Devices in Electric Power Substations
IEC 61850-3
Communication Networks and Systems in Substations – Part 3: General
Requirements
Test
Description
ESD
Radiated RFI
Burst (Fast
Transient)
Surge
Induced
(Conducted)
RFI
Magnetic Field
Enclosure
Contact
Enclosure Air
Enclosure Ports
Signal Ports
± 4 kV @ 2.5 kHz
DC Line-to-Line
AC Line-to-Line
Earth
Ground Ports
Signal Ports
± 4 kV Line-to-Ground,
± 2 kV Line-to-Line
DC Line-to-Line
± 2 kV Line-to-Ground,
± 1 kV Line-to-Line
AC Line-to-Line
± 4 kV Line-to-Ground,
± 2 kV Line-to-Line
Signal Ports
DC Line-to-Line
AC Line-to-Line
Earth
Ground Ports
Enclosure Ports
40 A/m continuous,
1000 A/m for 1 s
1000 A/m for 1 s
Test Levels
± 8 kV
± 15 kV
20 V/m
RUGGEDCOM-
severity levels.
± 4 kV
± 4 kV
± 4 kV
10 V
10 V
10 V
10 V
RUGGEDCOM-
severity levels.
Installation Manual, 01/2021, C79000-G8976-1037-06
Severity
Levels
4
4
specified
a
Note
4
4
4
4
3
4
3
3
3
3
specified
5