Certification
6.2 EMC and Environmental Type Tests
Dielectric Strength
Environmental Type Tests
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
30
Description
AC Line-to-Line
Signal Ports
DC Line-to-Line
AC Line-to-Line
Test
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Levels
5 kV
2 kV
1.5 kV
2 kV
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g @ 10-150 Hz
30 g @ 11 ms