Installing the Device
2.3 Connecting Power
The following shows the proper relay connections.
1
2
3
Figure 2.3
2.3

Connecting Power

The RUGGEDCOM RS950G supports a single integrated high AC/DC or low DC power
supply
IMPORTANT
IMPORTANT
Siemens requires the use of external surge protection in VDSL applications where
the line may be subject to surges greater than that for which the device is rated. Use
the following specifications as a guide for VDSL external surge protection:
10
1
2
3
Normally Open
Common
Normally Closed
Failsafe Alarm Relay Wiring
For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker
must be installed.
For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker
must be installed.
Use minimum #16 gage wiring when connecting terminal blocks.
Equipment must be installed according to applicable local wiring codes and
standards.
All line-to-ground transient energy is shunted to the Surge Ground terminal. In
cases where users require the inputs to be isolated from ground, remove the
ground braid between Surge and Chassis Ground. Note that all line-to-ground
transient protection circuitry will be disabled.
Clamping Voltage: 50 V to 200 V
Insertion Loss: < 0.1 dB at 10 MHz
Peak Surge Current: 10 kA, 8x20µs waveform
RUGGEDCOM RS950G
Installation Manual, 01/2021, C79000-G8976-1037-06