MAINTENANCE

Maintenance Schedule servicing is essential to
ensure the cooler operates efficiently for many
years. It must be carried out by a qualified,
licensed service technician.
It is important to note that all evaporative
coolers have components that may need
periodic replacement (eg. filter pads, hoses,
o-rings etc).
Note! It is important that only new Seeley
International factory authorised replacement
parts be used in this cooler. Failure to do so
may result in voidance of the factory warranty,
improper cooler and unsafe operation.
For detailed servicing requirements refer to the
Maintenance Schedule section.
Note! Failure to carry out the Maintenance
Schedule services will void your warranty
cover.
While installation is not covered by warranty
(e.g. duct work, roof penetrations, electrical
and water connections etc.), these items
should be checked as they can affect the
performance (and/or safety) of the cooler.
For this reason they are included in the
Maintenance Schedule.

HEALTH REGULATIONS

In some regions, regulations require that
evaporative air coolers be serviced at specific
intervals. Ensure all maintenance is done
in accordance with any local and national
regulations (e.g. AS/NZ 3666.2:2011).
LCQ / LCS / LCQI / LPQI / BMQ / CPQ / TBQ / TBS / TBQI / TBSI OWNER'S MANUAL |
ACCESS FOR SERVICING AND
MAINTENANCE
WARNING! As your cooler is mounted on
the roof, we suggest that any maintenance
or checks be carried out by an authorised
Seeley International dealer or service agent.
Climbing onto the roof can be hazardous
and could result in injury to you and
damage to your property.
Working at heights requires additional safety
precautions. Required clearances around
the cooler for maintenance and servicing are
shown below.
FLAT TANK
1.0m (3.5')
REAR
ALL COOLERS
1.0m (3.5')
FRONT
ALL COOLERS
1.0m (3.5')
Specific job sites may incur additional charges
for servicing in order to provide safe access to
the cooler for servicing, which may include, but
not limited to sites:-
with a roof pitch >30°
with limited access to the roof
where roof material or the condition of
does not allow safe access
where the roof access point is > 4m
above ground level
where the cooler is located too close to a
fall edge
which are not structurally capable of
supporting the weight of the cooler and
service technicians
Extra service or warranty charges may
apply for the cost of any equipment or
additional labour involved in providing safe
access to the cooler.
SLOPE TANK
0.6m (2')
ALL COOLERS
1.0m (3.5')
ILL2645-C