TROUBLESHOOTING

Symptom
Unpleasant odour
Inadequate cooling
Cooler turns ON and OFF
If your controller prompts you to call a service agent, please contact your local Seeley International
authorised dealer or the service number on the back of this manual.
|
12
Cause
Odour from the new pads
Dry pads
Dry patches in pads
(LPQI Models only)
Insufficient exhaust openings
for conditioned air
Excessive ambient humidity
Fault in the cooler
Action
• Use the 'Pad Flush' function in
the SETTINGS menu of your
MagIQtouch Controller to flush
pads.
• Fill tank, run pump for a short
period to wash pads, drain tank,
refill and repeat several times
if odour persists. Odour will
dissipate after a number of hours
of operation.
Ensure the water supply is turned
on. Then check the water flow to
the pads.
Check for blockages inside the lid
water distribution channels by lifting
up the rubber channel cover. Clear
out any debris.
Ensure the rubber channel cover
is refitted and pressed down flush
all the way around the lid before
refitting pad frames or running the
pump.
Ensure sufficient exhaust openings.
On days during the summer when
the ambient humidity is high,
the cooler will not reduce the
temperature as much as on drier
days.
Contact your Seeley International
authorised dealer or service
number.