Separator Kit Installation - Immergas VICTRIX OMNIA Instructions And Recommendations

Hide thumbs Also See for VICTRIX OMNIA:
Table of Contents

Advertisement

Extensions for Ø 80/125 vertical kit (Fig. 25)
The kit with this configuration can be extended to a max. straight
vertical length of 32 m, including the terminal. If additional com-
ponents are assembled, the length equivalent to the maximum al-
lowed must be subtracted. In this case the special extensions must
be requested.

1.18 SEPARATOR KIT INSTALLATION

Type C configuration, sealed chamber and fan assisted,
separator kit Ø 80/80
This kit allows air to come in from outside the building and the
exhaust to exit from the chimney, flue or intubated duct through
divided flue exhaust and air intake pipes.
Combustion products are expelled from pipe (S) (in plastic, so as
to resist acid condensate).
Air is taken in through duct (A) for combustion (this is also in
plastic).
The intake pipe (A) can be installed either on the right or left hand
side of the central exhaust pipe (S).
Both ducts can be routed in any direction.
Mounting the separator kit Ø 80/80 (Fig. 26):
1. Install the concentric flange (2) on the central hole of the boil-
er, positioning gasket (1) with the circular projections down-
wards in contact with the boiler flange.
2. Tighten with the hexagonal head and flat point screws provid-
ed in the kit.
3. Replace the flat flange present in the lateral hole with respect to
the central one (according to needs) with the flange (3), posi-
tioning the gasket (2) already present in the boiler
4. Tighten with the supplied self-tapping screws with drill bit.
5. Fit the bends with male side (smooth) (5) in the female side of
the flanges (3 and 4).
28
6. Fit the intake terminal (6) with the male side (smooth) in the
female side of the bend (5) up to the end stop, ensuring that the
internal and external wall sealing plates are fitted
7. Fit the exhaust pipe (9) with the male end (smooth) to the fe-
male end of the bend (5) up to the end stop; making sure that
the internal wall sealing plate has been fitted, this will ensure
sealing and joining of the elements making up the kit.
C
33
S
7
9
4
1
The kit includes (Fig. 26):
No.1 Exhaust gasket (1)
No.1 Flange gasket (2)
No.1 Female intake flange (3)
25
No.1 Female exhaust flange (4)
No.2 Bend 90° Ø 80 (5)
No.1 Intake terminal Ø 80 (6)
No.2 Internal wall sealing plates (7)
No.1 External wall sealing plate (8)
No.1 Exhaust pipe Ø 80 (9)
*
to complete C53 configuration, also provide for a
"green range" roof discharge terminal.
The configuration on walls opposite the building is not allowed.
Installation clearances (Fig. 27)
The minimum installation clearance measurements of the Ø
80/80 separator terminal kit have been stated in some limit condi-
tions.
5
5
6
7
A
3
2
C
* - C
53
83
8
26
C
43
27