Id
Parameter
Parameter
G
Gas type
In the event of an alteration, anomaly "E62" appears and complete calibration is required.
Id
Parameter
Parameter
n
Boiler model
In the event of an alteration, anomaly "E62" appears and complete calibration is required.
Id
Parameter
Parameter
S0
Min output
S1
Max output
S2
Ignition output
In the event of an alteration, anomaly "E62" appears and complete calibration is required.
Id
Parameter
Parameter
P0
DHW max
P1
Min output
Central heating
P2
max
P3
-
P4
-
P5
-
Pump function-
P6
ing
External probe
P7
correction
P8
-
62
Description
Defines operation with methane gas
Defines operation with LPG gas
Defines operation with propane air gas
(can be activated by means of a special menu)
Description
Define the boiler model
Description
The P.C.B. defines the operating mode and the boiler output
according to the combination of several parameters. The
proper operating output of the appliance is defined
according to the combination of the parameters of menus
"n" and "F". For this reason it is recommended not to alter the
parameters of this menu in order not to compromise the
proper operation of the boiler.
Description
Defines the maximum heat output percentage of the boiler
during the D.H.W. phase compared to the maximum heat
output available
Defines the minimum heat output percentage of the boiler
compared to the minimum heat output available
Defines the maximum heat output percentage of the boiler
during the central heating mode compared to the maximum
heat output available
Not used
Not used
Not used
The pump can function in two ways.
0 intermittent: in winter "mode" the circulator is managed by
the room thermostat or by the remote control.
1 continuous: in "winter" mode the circulator is always
powered and is therefore always in operation
If the reading of the external probe is not correct it is possible
to correct it in order to compensate any environmental
factors.
Not used
Range
Default
nG
LG
nG
AP
Range
Default
0 = Victrix
0 ÷ 1
Omnia
1 = Not used
Range
Default
750 ÷ 1700
1300 (nG/LG)
rpm
S0 ÷ 6900 rpm 6200 (nG/LG)
2000 ÷ 4500
3200 (nG/LG)
rpm
Range
Default
0 - 99 %
99%
0 - P2
0%
0 - 99%
79%
-
-
-
-
-
-
0 - 1
0
-9 ÷ 9 K
0
-
-
Value
value
Value
value
Value
value
Value
value