Menu Overview Functions Menu „Uf 1-10 - KERN CIB Operating Manual

Counting balances
Table of Contents

Advertisement

10.2 Menu overview functions menu „UF 1-10"
Menu item
864650
UF-1
bat. 6.4
Internal value/
Battery capacity
350994
UF-2
Average piece
AavG 1
weight
AavG 2
UF-3
AoFF00
Auto-Off
UF-4
Lit 0
Background
Lit 1
illumination
Lit 2
UF-5
„A" first value:
Settings of
0
totalizing
1
function
„B" second value:
0
1
UF-6
RS232 interface
UF-7
Speed 1
A/D Update
Speed 2
Rate
Speed 3
CIB-BA-e-2010
Submenu
Internal value
Shows the current volt number of the battery
Internal value
Average piece weight for reference optimisation
On
Off
Background illumination automatic
Background illumination on:
Background illumination off
Stability must be displayed
Stability needs not to be displayed
The zero throughput must take place to carry out
the next totalizing
The zero throughput needs not to take place to
carry out the next totalizing
No interface available
Speed can be set from 1 to 3 (1 = slow (7.5hz),
2 = medium (15hz), 3 = fast (30hz)
Description of function
AoFF00 is defined as default
Values of 0-99 can be entered (in
minutes)
Value 00 - Auto off switched off