Elesa DD51-E-RF Operating Instructions Manual

Electronic digital position indicators

Advertisement

Quick Links

OPERATING INSTRUCTIONS
Electronic digital position indicators
DD51-E-RF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DD51-E-RF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elesa DD51-E-RF

  • Page 1 OPERATING INSTRUCTIONS Electronic digital position indicators DD51-E-RF...
  • Page 2: Table Of Contents

    CE.99302-W2 DD51-E-RF-W2-SST-F.14-IP65-C2 CE999302-W2 DD51-E-RF-W2-SST-F.1/2-IP65-C2 CE.99301-W2 DD51-E-RF-W2-SST-F.14-IP65-C3 CE999301-W2 DD51-E-RF-W2-SST-F.1/2-IP65-C3 CE.99305-W2 DD51-E-RF-W2-SST-F.14-IP65-C55 CE999305-W2 DD51-E-RF-W2-SST-F.1/2-IP65-C55 CE999313-W2 DD51-E-RF-W2-SST-F.1/2-IP67-C1 CE.99313-W2 DD51-E-RF-W2-SST-F .14-IP67-C1 CE999312-W2 DD51-E-RF-W2-SST-F.1/2-IP67-C2 CE.99312-W2 DD51-E-RF-W2-SST-F .14-IP67-C2 CE999311-W2 DD51-E-RF-W2-SST-F.1/2-IP67-C3 CE.99311-W2 DD51-E-RF-W2-SST-F .14-IP67-C3 CE999315-W2 DD51-E-RF-W2-SST-F.1/2-IP67-C55 CE.99315-W2 DD51-E-RF-W2-SST-F .14-IP67-C55 Contents 1. Safety Instructions 2. Version and functionality 3.
  • Page 3 DD51-E-RF Electronic digital position indicators 8.7.3 Indications for reaching the target position 8.7.4 Disabling the target 8.7.5 Display in target mode 9. RF functionalities 9.1 Device ID 9.2 Binding 9.3 Heartbeat 9.4 Targets 9.5 RF communication quality . Programming mode 10.1 Input of numeric parameters...
  • Page 4: Safety Instructions

    DD51-E-RF Electronic digital position indicators 1. Safety Instructions This device has been designed and manufactured in accordance with current legislation. To keep the product in this state, it must be assembled and used correctly, in strict compliance with the instructions contained in this instruction manual and with the following specific safety precautions.
  • Page 5: Version And Functionality

    In case of specific need, it is recommended to ask the Elesa service staff for assistance. Elesa reserves the right, without further communication, to make improvements, additions, corrections to the menu items, that do not modify or affect the described functionality of the product but are necessary for the continuous improvement to which these products are subjected.
  • Page 6: Device Description

    > 20 ° C and <30°C and default setup. Furthermore, this value refers to the condition of the device when it leaves the Elesa factory. Long storage times must always be considered for the estimation of the battery life when the device becomes operational.
  • Page 7: Installation

    DD51-E-RF Electronic digital position indicators 4. Installation 1.Drill a Ø 6x10 mm hole in the machine body with a 22 mm centre distance from the shaft for mounting the rear reference pin. 2. Mount the device on the shaft and make sure the reference pin fits into the hole.
  • Page 8: Key Functions

    DD51-E-RF Electronic digital position indicators 6. Key functions Using these 3 keys is possible to move between the menus and set the working parameters. Furthermore is possible to configure some additional function using one or a couple of keys. Key Or Key...
  • Page 9 DD51-E-RF Electronic digital position indicators Key Or Key Operating Programming Combination Mode Mode While entering the numeric Select between absolute value of a and relative measure parameter: mode: Short press: It is possible to choose increment the one of the following op-...
  • Page 10: Switching On/Off The Device

    DD51-E-RF Electronic digital position indicators Key Or Key Operating Programming Combination Mode Mode Programmable for one of the following functions (see menu item – 0 _ _ _ 0 chap.10.3): P_OrG [DEFAULT]: shows and allows you to set the OrG parameter.
  • Page 11: Switching Off The Device (For Storage Only)

    DD51-E-RF Electronic digital position indicators 7.2 Switching off the device (for storage only) To switch the system off: - select the rESEt item from the main menu (see chap.8.3) - using the key , scroll through the items to select OFF .
  • Page 12: Resolution

    DD51-E-RF Electronic digital position indicators WARNING:The value of the Origin parameters and the offsets are the same for the mm and inch units of measure and are displayed, depending on the unit of measure in use (see chap. 8.4), with the appropriate conversion coefficient. In the case of degrees, these parameters are totally different and independent from the previous ones.
  • Page 13: Unit Of Measure Selection

    DD51-E-RF Electronic digital position indicators 8.4 Unit of measure selection Press the key to select the required unit of measure. The available options are millimetres, inches and degrees. The selected measure mode is indicated on the display by the symbols:...
  • Page 14: Direct Programming Of Origin, Offset And Step Parameters

    (mm and inch) and for degrees measurements. 8.7 Targets The DD51-E-RF permits you to set up to 32 Targets allowing you to store any relevant and frequently used position. Models all rights reserved in accordance with the law. Always mention...
  • Page 15: Programming The Targets

    DD51-E-RF Electronic digital position indicators 8.7.1 Programming the targets To program the targets: - activate the Programming Mode - select tArGE in the main menu (see chap. 10.3) - select PrOGt (see chap. 10.4) - select the desired memory location (from PtG00 to PtG31 )
  • Page 16: Disabling The Target

    DD51-E-RF Electronic digital position indicators The target direction indicators work, depending on the, dir and PtOLL parameters, as in the following table T = target value set M = actual measure PtOLL Toll = tolerance (see M < T - Toll...
  • Page 17: Rf Functionalities

    Elesa wireless network is made by the following components: - One control unit UC-RF - Max 36 device as DD51-E-RF , DD52R-E-RF o MPI-R10-RF . The UC-RF exchanges information with the DD51-E-RF via radio frequency and makes it possible to:...
  • Page 18: Device Id

    DD51-E-RF Electronic digital position indicators 9.1 Device ID Each RF device of the W2 series is distinguished by a 4-byte identifier uniquely assigned at the factory. This number, called device ID, can be viewed by selecting the dd_Id item in the Radio menu.
  • Page 19: Heartbeat

    DD51-E-RF Electronic digital position indicators table of associated devices of the latter. Otherwise, as soon as the two devices were to get back in contact, they would re- associate. 9.3 Heartbeat Remote devices broadcast their position and status at a fixed rate. By analogy, this transmission is called heartbeat (HB) and its frequency the heartbeat rate.
  • Page 20: Targets

    Electronic digital position indicators 9.4 Targets Using the DD51-E-RF , the target positions can be sent from the PLC to the device via the UC-RF control unit. When a target is transmitted, it behaves in the same way described in chap. 8.7.
  • Page 21: Programmable Parameters (In Alphabetical Order)

    DD51-E-RF Electronic digital position indicators By keeping the button pressed, the selected, flashing digit will begin to decrease in value, one unit at a time, with a certain frequency, as long as the button is pressed. When the digit reaches the value 0, by keeping the key pressed, 9 will be displayed and the counting will start again.
  • Page 22 DD51-E-RF Electronic digital position indicators Parameter Description Available options Default Update frequency of radio Heart beat rate readings: 0÷7 507.8 ms 1015.6 ms Hb rt 2031,2 ms 4062.4 ms … …. 64.3 s Fast Heart Update frequency of radio readings:0÷7 beat rate 126.95ms...
  • Page 23 DD51-E-RF Electronic digital position indicators Parameter Description Available options Default Tolerance The settable values depend on of target the unit of measure in use: 0.10 position inches: mm: 0.01 ÷ 9.99 Ptoll 0.004 inches: 0.001 ÷ 0.393 Degrees: degrees: 0.01 ÷ 9.99 0.10...
  • Page 24: Main Menu Tree

    DD51-E-RF Electronic digital position indicators Parameter Description Available options Default tArGe Target It is possible to store up to 32 Target positions. positions The settable values depend on the resolution set as follows: Res = 1 : -19999 ÷ 99999 Res = 0.1 : -1999.9 ÷...
  • Page 25 DD51-E-RF Electronic digital position indicators 0° dISPL 180° SPEEd 1000 See chap. 10.5 rAdio 0.01 ÷ 9.99 PtoLL inch 0.001 ÷ 0.393 degree 0.01÷9.99 See chap. 10.4 tArGE nodEG 0 _ _ _ _ _ _ 0 _ _ ArCLr...
  • Page 26: Target Menu Tree

    DD51-E-RF Electronic digital position indicators 10.4 Target menu tree LtG00 LOAdt LtG31 -19999 ÷ 99999 PtG00 PrOGt -19999 ÷ 99999 PtG31 The values must be divided by the number of decimal places of the resolution set. 10.5. Radio menu tree 0÷7...
  • Page 27: Lcd Test

    DD51-E-RF Electronic digital position indicators - press the key to confirm. To restore the factory settings on the device: - select the voice rESEt from the main menu (see chap. 10.3) - using the key select ALL . - press the key to confirm, the device will restart as after the swicth-on.
  • Page 28: Password

    DD51-E-RF Electronic digital position indicators In case of need for support, the data in the Info menu must be noted and provided to Elesa 10.6.4 Password You can avoid unwanted access to the device menu by choosing “ on “ in the PASS menu item. By default the password is set to: 22011.
  • Page 29: Display Messages And Troubleshooting

    DD51-E-RF Electronic digital position indicators 12. Display messages and troubleshoting Message on Description Action the display In Operational mode, the device continues to correctly measure the position of the shaft. If the measured value is within the capacity of the display, it will be shown correctly.
  • Page 30 DD51-E-RF Electronic digital position indicators EU DECLARATION OF CONFORMITY (DoC) COMPANY NAME: Elesa S.p.a. POSTAL ADDRESS: Via Pompei 29 POSTCODE AND CITY: 20900 Monza TELEPHONE NUMBER: +39 039 28111 E-MAIL ADDRESS: info@elesa.com Declare that the DoC is issued under our sole responsibility and...
  • Page 31 The Company Elesa S.p.A. can neither be held legally responsible nor liable for lacking or incorrect information and the ensuing consequences. The Company Elesa S.p.A. reserves the right to alter or improve the or parts of them and/ electronic position indicators or the enclosed brochures without prior notice ELESA S.p.A.

Table of Contents