4.2 Storage

Transport, storage, assembly and Installation
Fig. 2: Lifting the DFDa 025 / 032 / 040
1
Lifting lug
The lifting lugs (1) on the pump housing are used to life the DFDa
025 / 032 / 040.
Fig. 3: Lifting the DFDa 060 / 070 / 080 / 100
Appropriate lifting equipment is used to lift the DFDa 060 / 070 /
080 / 100, as shown in Fig. 3.
Storage
The pump hose should be removed from the housing during
n
the period of storage
For storage durations longer than 60 days, the coupling sur‐
n
faces (terminals, reducing adaptors, motors) are to be pro‐
tected with suitable antioxidant agents
For environmental conditions for storage and transportation
n
Ä Chapter 4.3.1 'Ambient conditions' on page 28
see
A0402
A0403