1.3 Identity Code for DULCO

DFDa DULCO
®

flex DFDa 025

Type
025
DFDa 025, 0.3 l/revolution
Power end/drive
000
Pump without power end/drive
Reduction gear system / 3 x 230 / 400 VAC
A11
0.55 kW, 18 rpm, 324 l/h, 15 bar
A12
0.75 kW, 28 rpm, 504 l/h, 15 bar
A13
0.75 kW, 39 rpm, 702 l/h, 10 bar
A14
0.75 kW, 45 rpm, 810 l/h, 5 bar
A15
1.10 kW, 55 rpm, 990 l/h, 5 bar
Gear motor with integrated frequency converter / 1x 230 VAC
A31
1.10 kW, 16 ... 55 rpm, 288 ... 990 l/h, 20 ... 70 Hz, 5 bar
A32
1.50 kW, 18 ... 63 rpm, 324 ... 1134 l/h, 20 ... 70 Hz, 5 bar
Gear motor (external frequency converter required) / 3 x 230 / 400 VAC
A41
0.75 kW, 4 ... 36 rpm, 72 ... 648 l/h, 7 ... 65 Hz, 15 bar
A42
1.10 kW, 6 ... 58 rpm, 108 ... 1044 l/h, 7 ... 65 Hz, 5 bar
A43
1.50 kW, 9 ... 86 rpm, 162 ... 1548 l/h, 7 ... 65 Hz, 5 bar
Hose material
0
B
E
®
flex DFDa 025
Identity code
NR
NBR
EPDM
Hydraulic connector
I
DIN flange, VA, DN25
J
DIN flange, PP, DN25
K
DIN flange PVDF/PTFE, DN25
L
ANSI flange, VA, 1"
Base plate
0
Base plate, lacquered steel
1
Base plate, stainless steel
2
Portable unit + lacquered steel base plate
3
Portable unit + stainless steel base plate
Leakage sensor
0
without leakage sensor
L
with leakage sensor
M
with leakage sensor + relay output