Step 4. UPS input connection: Plug the UPS into a two-pole, three-wire,
grounded receptacle only. Avoid using extension cords.
Step 5. UPS output connection: For socket-type outputs there two kinds
of output: programmable outlets and general outlets. Please connect non-
critical devices to the programmable outlets and critical devices to the
general outlets. During power failure, you may extend the backup time to
critical devices by setting shorter backup time for non critical devices.
CAUTION
Do NOT plug LASER
PRINTERS into any of
the outlets.
Step 6. Communication connection: To allow for unattended UPS
shutdown/start-up and status monitoring, connect the communication
cable one end to the USB/RS-232 port and the other to the
communication port of your PC. With the monitoring software installed,
you can schedule UPS shutdown/start-up and monitor UPS status
through PC. The UPS is equipped with a slot for either SNMP or AS400
card. When installing either SNMP or AS400 card in the UPS, it will
provide advanced communication and monitoring options.
Communication port:
USB Port
RS-232 Port
NOTE!
USB port and RS-232 port can't work at the same time.
12
Do NOT plug any SURGE
STRIPS into any of the
outlets.
Intelligent slot
Step 7. Network connection: Connect a single modem/phone/fax line
into surge-protected "IN" outlet on the back panel of the UPS unit.
Connect from "OUT" outlet to the equipment with another modem/fax/
phone line cable.
Network/Fax/Phone surge port:
Step 8. Disable and enable EPO function: Keep the pin 1 and pin 2 closed
for UPS normal operation.
It's in closed status for UPS
normal operation.
Step 9. Turn on the UPS: Press the ON/Mute button on the front panel
for two seconds to power on the UPS.
NOTE!
The battery charges fully during the first five hours of normal operation. Do
not expect full battery run capability during this initial charge period.
Step 10. Install software: For optimal computer system protection, install
UPS monitoring software to fully configure UPS shutdown. Use supplied
RS-232 or USB communication cable to connect RS-232/USB port of
UPS and RS-232/USB port of PC. Install the UPS monitoring software
from
https://www.power-software-download.com/viewpower.html
configure UPS shutdown.
To activate EPO
function, remove
these two screws.