Figure 9: Connect a Grounding Cable to a PTX10001-36MR Device
3. Dress the grounding cable and ensure that it does not touch or block access to other device components and that it
does not drape where people could trip over it.

Connect AC/HVDC Power to the PTX10001-36MR

This procedure is for AC/HVDC installations only. For DC installations, see Connect DC Power to the PTX10001-36MR.
CAUTION:
The power supplies automatically detect whether there is AC or HVDC input voltage and manage the power accordingly.
Each 3000 W AC/HVDC power supply module has a single AC or HVDC input and provides 12 V of power to the system.
The power supply in a PTX10001-36MR is a hot-removable and hot-insertable field-replaceable unit (FRU). After removing
the power cord from an individual power supply, you can remove and replace it without powering off the router or
disrupting router functions.
Before you begin to connect AC/HVDC power to the PTX10001-36MR:
Ensure that you have a power cord appropriate for your geographical location available to connect AC power to the
router. See PTX10001-36MR Power Cord Specifications.
Read General Electrical Safety Guidelines and Warnings and Action to Take After an Electrical Accident.
Ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage (see Prevention
of Electrostatic Discharge Damage).
Ensure that you have connected the PTX10001-36MR chassis to earth ground.
Do not mix AC/HVDC and DC power supplies in the same chassis.