Raytheon Anschütz STD 22 Compact GYRO COMPASS Installation And Service Manual page 96

Hide thumbs Also See for STD 22 Compact GYRO COMPASS:
Table of Contents

Advertisement

-- Pour approximately 840 cm
(look for the identifying label).
The supporting liquid must be at room temperature (over 25° C) and the measuring
cone should fill half the measuring range (diameter).
The following photograph shows the measuring cone for the liquid level.
Figure 47: Measuring cone for supporting liquid level
-- Discard any unused supporting liquid; no special measures are needed for disposal.
-- Re-close the filling opening for supporting liquid, check that it is properly sealed.
-- Re-insert the ventilation screw, check that it is properly sealed.
3646/110--233.DOC010302
Installation and Service manual
Compass STD 22
3
of supporting liquid in the appropriate filling opening
This picture only shows the situation at the start of operation
(after filling for the first time or after changing the supporting
liquid --> cold supporting liquid); during operation, the dark
circle in the measuring cone is smaller.
86
Supporting liquid level
Measuring cone
Edition: Nov. 28, 2005