Raytheon Anschütz STD 22 Compact GYRO COMPASS Installation And Service Manual page 129

Hide thumbs Also See for STD 22 Compact GYRO COMPASS:
Table of Contents

Advertisement

Serial
no.
12
Step 2
12
Step 3
12
Step 4
12
Step 5
12
Step 6
12
Step 7
12
Step 8
12
Step 9
12
Step 10
12
Step 11
12
Step 12
12
Step 13
Edition: Feb. 17, 2006
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
DIP switch setting
Function
Indicate alignment error
Indicate SEC (Speed Error Correction)
Indicate ship's mains input voltage (24VDC)
Nominal value: 18.0....36.0V
Indicate internal operating voltage of Power
Supply PCB (14VDC)
Nominal value: 14.0...16.0V
Indicate encoder supply voltage (15VDC)
Nominal Value: 14.5...15.5V
Indicate inductive DC transmission supply
voltage (60VDC)
Nominal value: 58.0....62.0V
Indicate internal operating voltage of Power
Supply PCB (19VDC)
Nominal value: 18.0...22.0V
Indicate present current due to inductive
transmission
Nominal value: 0.05...4.0A
typical: 2.0 A
Indicate operating voltage of heating
Nominal value: 27.0...32.0V
Indicate heating voltage at heating element
Nominal value: 0...23.5V
Indicate temperature of the supporting liquid
in °C
Nominal value:
Operating temperature 49.4...50.1°C
Indicate supporting liquid
2.0 -- 1.6 = level OK
0.1 -- 0.0 = level too low
119
Compass
STD 22
3646/110--233.DOC010302

Advertisement

Table of Contents
loading

This manual is also suitable for:

Std 22 gyro compass110-233

Table of Contents