Summary of Contents for Raytheon Anschütz 108-010.NG001 E01
Page 1
Magnetic Sonde Operator and Service Manual Type: 108-010.NG001 E01 Type: 108-010.NG002 E01 Type: 108-010.NG003 E01 Type: 108-010.NG004 E01 Edition:003 4423...
Page 2
Copyright Dieses Dokument sowie dessen Inhalt sind urheberrechtlich This document and its content are copyright protected. Distribution, geschützt. Die Weitergabe, Vervielfältigung und Speicherung sowie reproduction and storage as well as translation and exploitation of die Übersetzung wie auch Verwendung dieses Dokuments oder this document and its content, in whole or in parts and regardless of dessen Inhalts, als Ganzes oder in Teilen und egal in welcher Form, what form, are prohibited without prior express written permission.
Magnetic Sonde Table of Contents Table of Contents List of Figures..............................III List of Tables................................ V List of Abbreviations............................VII 1 Introduction..............................1 1.1 Preliminary Remarks..........................1 2 Safety................................2 2.1 General Safety Regulations........................2 2.2 General Safety Instructions........................2 2.3 Electrostatic Sensitive Devices........................ 3 3 List of Annex Drawings..........................5 4 Description...............................
Page 4
7.4.3.4 Replace Magnetic Sonde 108-010.NG004 E01..............29 7.4.4 Replace Holders of Magnetic Sonde.................... 30 7.4.4.1 Replace Holder for 108-010.NG001, 108-010.NG002 and 108-010.NG004......30 7.4.4.2 Replace Holder for 108-010.NG003..................32 7.4.4.3 Replace Holder for 108-010.NG001 E01, 108-010.NG002 E01 and 108-010.NG004 E01..............................35 7.4.4.4 Replace Holder for 108-010.NG003 E01................37 7.4.4.5 Install Holder......................... 39 7.4.5 Replace Junction Box........................41...
Magnetic Sonde List of Tables List of Tables Tab. 1: Dimensional Drawings..........................5 Tab. 2: Wiring Drawings............................5 Tab. 3: Special Tools, Measurement and Test Equipment.................. 13 Tab. 4: Consumables............................13 Edition:003 4423...
Page 8
Magnetic Sonde List of Tables 4423 Edition:003...
Magnetic Sonde List of Abbreviations List of Abbreviations ESD Protected Area Electrostatic Sensitive Device ISPC Illustrated Spare Parts Catalog Edition:003 4423...
Page 10
Magnetic Sonde List of Abbreviations 4423 VIII Edition:003...
Magnetic Sonde 1 Introduction 1 Introduction 1.1 Preliminary Remarks The present manual is a description and reference book only. It is intended to answer questions and to solve problems in the quickest possible manner. Read and follow the instructions and notes in this manual before operating the equipment. For this purpose, refer to the table of contents and read the corresponding chapters thoroughly.
Magnetic Sonde 2 Safety 2 Safety 2.1 General Safety Regulations The following safety symbols are used in this manual: WARNING! Warning statements indicate a hazardous situation that, if not avoided, could result in minor, moderate or serious injury, or death Consequence •...
Magnetic Sonde 2 Safety WARNING! Danger due to voltage-regulated devices Risk of death or serious injury that is caused by electrical shock • Switch off voltage supply if the wires have damaged insulation. • Only skilled electricians must perform work on the electric system. •...
Page 14
Magnetic Sonde 2 Safety The product and all electronic parts of the product are susceptible to ESD. The product must be handled with protection especially when removing the covers, touching the connectors or handling the product components. sensitive parts must be packed in metallized protective bags during shipping and handling outside any ESD Protected Area (EPA).
The magnetic sonde converts the visual display of the magnetic compass into an electrical signal. 4.2 Hardware Breakdown of the System / Equipment Fig. 2: Hardware Breakdown of the System/Equipment 108-010.NG001 E01 108-010.NG002 E01 108-010.NG003 E01 108-010.NG004 E01 4423 Edition:003...
Magnetic Sonde 4 Description 4.3 Labeling Position Fig. 3: Magnetic Sonde, Labeling Position 4.4 Technical Data Dimensions Height 29.5 mm Width 58.5 mm Depth 58.5 mm Weight approx. 0.16 kg Protection Class IP 65 Voltage Supply acc. to the connected equipment Power Consumption Operation Temperature -25 °C to +55 °C...
Magnetic Sonde 4 Description Type 108-010. NG002 E01 Type 108-010. NG002 E01 has a connection cable with stranded wires that are fitted with plug-in terminals. It has to be connected directly to the terminal strips of the related equipment. Type 108-010. NG003 E01 Type 108-010.
Magnetic Sonde 5 Operation 5 Operation 5.1 Safety Instructions for Operation WARNING! Danger due to improper operation and purpose Risk of serious injury and material damage • Use product only for the intended purpose. • Perform operation steps according to this manual. WARNING! Danger due to operation by unskilled personnel Risk of serious injury and material damage...
Magnetic Sonde 5 Operation 5.4 Setting Out of Operation 5.4.1 Setting Out of Operation Procedures The magnetic sonde is not a stand-alone system. The setting out of operation is performed via the connected system or equipment. 5.4.2 Post-Operation Procedures Procedure 1. Switch off the power supply of the connected system or equipment. 5.4.3 ...
Magnetic Sonde 6 Troubleshooting 6 Troubleshooting 6.1 Troubleshooting Table Failure Possible Cause Remedy The connected sys- Connected sys- Set the connected tem or equipment re- tem or equipment is system or equipment ceives no data. switched off. into operation. Cable connection Check the cable between the junction connection between...
Magnetic Sonde 7 Installation and Maintenance 7 Installation and Maintenance 7.1 Safety Instructions for Installation and Maintenance WARNING! Danger due to maintenance and service by unskilled personnel Risk of serious injury and material damage • Keep all unskilled personnel away from the working area. •...
Magnetic Sonde 7 Installation and Maintenance Note All spare parts that are produced by Raytheon Anschütz GmbH are identified in the ISPC by a seven-digit part number. This part number is included in the serial number on the type plate of the equipment. The first 7 digits of the serial number are formed by the part number.
Magnetic Sonde 7 Installation and Maintenance Consumables, Materials and Expendables Tie, cable 06-0000 04 As required Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage • Observe all general safety instructions. •...
Magnetic Sonde 7 Installation and Maintenance 2. Protect the magnetic compass from turning back. 3. Clean and degrease the glass pane (Fig. 4/1) of the magnetic compass with a suitable agent. 4. Cut out the centering mask (Fig. 4/2) and use it to mark the center of the glass pane. 5.
Magnetic Sonde 7 Installation and Maintenance Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage • Observe all general safety instructions. • Observe all safety instructions for maintenance. Procedure Fig. 5: Install Junction Box Junction Box Cover Screw...
Magnetic Sonde 7 Installation and Maintenance Fig. 6: Drilling Scheme, Junction Box 2. Loosen the 4 screws (Fig. 6/3). 3. Remove the cover (Fig. 6/2). 4. Install the junction box (Fig. 5/1) with 2 suitable screws. 5. Connect the cable of the responding system or equipment to the terminal strip, see attached wiring diagram.
Magnetic Sonde 7 Installation and Maintenance Note The terminal assignment of the vessel cable connection in the junction box depends on the connection diagrams of the responding system or equipment. 6. Install the cover. 7. Tighten the 4 screws. Close Up 1.
Magnetic Sonde 7 Installation and Maintenance a) 108-010.NG001 E01 - Connect the connecting cable of the magnetic sonde to junction box Type 134-089. b) 108-010.NG002 E01 - Connect the connecting cable of the magnetic sonde directly to the related system or equipment.
Magnetic Sonde 7 Installation and Maintenance Spares No spares Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage • Observe all general safety instructions. • Observe all safety instructions for maintenance. Procedure Fig.
Magnetic Sonde 7 Installation and Maintenance 7.3.5 Adjust Magnetic Sonde Requirements Required Conditions 1. The magnetic sonde is connected to the related system or equipment. Required Persons 1 Maintainer 1.0 h 1 Assistant 1.0 h Support Equipment Label, AHEAD 05-0000 04 1 EA Consumables, Materials and Expendables Loctite 243...
Magnetic Sonde 7 Installation and Maintenance Procedure Fig. 9: Adjust Magnetic Sonde Screw Magnetic Sonde Label 1. Switch the course indication on the gyro operator unit to Uncorrected Heading, see related documentation. 2. Loosen the 3 screws (Fig. 9/1) slightly. 3. Check the sense of rotation. a) Turn the magnetic sonde (Fig.
Magnetic Sonde 7 Installation and Maintenance ► The course indication of the connected system or equipment must match the course indication of the magnetic compass. Note Repeat the deflection of the magnetic compass and check the course 3 to 4 times. 6.
Magnetic Sonde 7 Installation and Maintenance Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage • Observe all general safety instructions. • Observe all safety instructions for maintenance. Procedure Fig. 10: Measuring Points of Magnetic Sonde 1.
Magnetic Sonde 7 Installation and Maintenance ► The nominal resistance must be 146 Ohms. Close Up 1. If the measured resistances deviate from the nominal values, replace the magnetic sonde, see chapter 7.4.3. 7.4.2 Remove Magnetic Sonde Requirements Required Persons 1 Maintainer 1.0 h Support Equipment Tool, operating...
Magnetic Sonde 7 Installation and Maintenance Procedure Fig. 11: Remove Holder with Magnetic Sonde Glass Pane Holder Plate 1. Turn the magnetic compass upside down, see related documentation. 2. Protect the magnetic compass from turning back. 3. Disconnect the magnetic sonde from the related system or equipment. 4.
Magnetic Sonde 7 Installation and Maintenance Close Up No close up 7.4.3 Replace Magnetic Sondes 7.4.3.1 Replace Magnetic Sonde 108-010.NG001 E01 Requirements Required Conditions No conditions Required Persons 1 Maintainer 0.1 h Support Equipment No support equipment Consumables, Materials and Expendables...
Magnetic Sonde 7 Installation and Maintenance Required Persons 1 Maintainer 0.1 h Support Equipment No support equipment Consumables, Materials and Expendables No consumables, materials and expendables Spares Sonde, magnetic 1 EA 01-0000 03 Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage •...
Magnetic Sonde 7 Installation and Maintenance Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage • Observe all general safety instructions. • Observe all safety instructions for maintenance. Procedure 1. Provide a new magnetic sonde. 2.
Magnetic Sonde 7 Installation and Maintenance Close Up 1. Install the magnetic sonde, see chapter 7.3.1. 7.4.4 Replace Holders of Magnetic Sonde 7.4.4.1 Replace Holder for 108-010.NG001, 108-010.NG002 and 108-010.NG004 Requirements Required Conditions 1. The holder with the magnetic sonde is removed from the magnetic compass, see chapter 7.4.2.
Magnetic Sonde 7 Installation and Maintenance Procedure Fig. 12: Replace Holder for 108-010.NG001, 108-010.NG002 and 108-010.NG004 Plate Ground Plate Screw Washer Magnetic Sonde Washer Spacer Thread Bar 1. Measure and note the distance between the plate (Fig. 12/1) and the ground plate (Fig.
Magnetic Sonde 7 Installation and Maintenance CAUTION! Hazard due to thread bars protrude through the ground plate Risk of damaging the glass pane of magnetic compass • Ensure the thread bars do not protrude through the ground plate. d) Secure the spacers with Loctite 648. 8.
Magnetic Sonde 7 Installation and Maintenance Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage • Observe all general safety instructions. • Observe all safety instructions for maintenance. Procedure Fig. 13: Replace Holder for 108-010.NG003 Lower Plate Ground Plate Screw...
Page 44
Magnetic Sonde 7 Installation and Maintenance 1. Measure and note the distance between the lower plate (Fig. 13/1) and the ground plate (Fig. 13/2). 2. Remove the 3 screws (Fig. 13/3) with washers (Fig. 13/4). 3. Remove the upper magnetic sonde (Fig.
Magnetic Sonde 7 Installation and Maintenance 7.4.4.3 Replace Holder for 108-010.NG001 E01, 108-010.NG002 E01 and 108-010.NG004 E01 Requirements Required Conditions 1. The holder with the magnetic sonde is removed from the magnetic compass, see chapter 7.4.2. Required Persons 1 Maintainer 1.0h...
Magnetic Sonde 7 Installation and Maintenance 7.4.4.4 Replace Holder for 108-010.NG003 E01 Requirements Required Conditions 1. The holder with the magnetic sonde is removed from the magnetic compass, see chapter 7.4.2. Required Persons 1 Maintainer 1.0 h Support Equipment No support equipment Consumables, Materials and Expendables Loctite 243 06-0000 03...
Magnetic Sonde 7 Installation and Maintenance 11.Remove the 3 nuts (Fig. 15/5) with washers (Fig. 15/6). 12.Remove the plate (Fig. 15/7). 13.Remove the 3 screws (Fig. 15/8) with washers (Fig. 15/9). 14.Remove the lower plate (Fig. 15/10). 15.Place the lower magnetic sonde (Fig.
Magnetic Sonde 7 Installation and Maintenance Safety Conditions WARNING! Danger due to nonadherence to safety instructions Risk of death or serious injury and material damage • Observe all general safety instructions. • Observe all safety instructions for maintenance. CAUTION! Hazard due to magnetic mounting material on the magnetic compass Risk of differing course display of the magnetic compass •...
Magnetic Sonde 7 Installation and Maintenance 5. Remove the protective paper (Fig. 16/3) from the adhesive rings. Note Do not touch the adhesive surface with your fingers. 6. Install the holder (Fig. 16/4) exactly to the marked center of the glass pane. 7.
Magnetic Sonde 7 Installation and Maintenance Procedure Fig. 17: Replace Junction Box Junction Box Cover Screw 1. Disconnect the junction box (Fig. 17/1) from the magnetic sonde and the connected system or equipment. 2. Loosen the 4 screws (Fig. 17/3). 3. Remove the cover (Fig.
Magnetic Sonde 7 Installation and Maintenance Fig. 18: Terminal Assignments of Junction Box CP 500JB Note The terminal assignment of the vessel cable connection in the junction box depends on the connection diagrams of the responding system or equipment. 13.Install the cover. 14.Tighten the 4 screws.
Magnetic Sonde 8 Transport and Storage 8 Transport and Storage 8.1 Preservation, Packing and Storage Preservation All components / devices require no special preservation procedures. Packing All components / devices are packable in customary packing. Take special care when packing electrostatic sensitive devices. CAUTION! Hazard to electrostatic sensitive device Risk of material damage...
Page 59
Magnetic Sonde Illustrated Spare Parts Catalog 4423 108-010.NG001 E01 108-010.NG002 E01 108-010.NG003 E01 108-010.NG004 E01 Edition:001...
Page 60
Dieses Dokument sowie dessen Inhalt sind This document and its content are copyright urheberrechtlich geschützt. Die Weitergabe, protected. Distribution, reproduction and Vervielfältigung und Speicherung sowie die storage as well as translation and exploitation of this document and its content, in whole or Übersetzung wie auch Verwendung dieses Dokuments oder dessen Inhalts, als Ganzes in parts and regardless of what form, are...
Page 61
Magnetic Sonde Illustrated Spare Parts Catalog Illustrated Spare Parts Catalog Content 00-0000 Magnetic Sondes, Variants 01-0000 Magnetic Sondes 02-0000 Holders 03-0000 Installation Kit 04-0000 Junction Boxes 05-0000 Special Tools and Test Equipment 06-0000 Consumables Edition:001 4423...
Page 62
Magnetic Sonde Illustrated Spare Parts Catalog Intentionally left blank Edition:001...
Page 63
Magnetic Sonde Illustrated Spare Parts Catalog Definitions Col. Description Fig. No. The figure number gives the relation to the respective figure. Item No. The item number gives the relation to the position number on the respective figure. Designation This column comprises the designation of a spare part. Supplier This column comprises the name of the manufacturer.
Page 64
Magnetic Sonde Illustrated Spare Parts Catalog Magnetic Sondes, Variants 00-0000, Sheet 1 of 1 4423 Edition:001...
Page 65
Magnetic Sonde Illustrated Spare Parts Catalog Fig. No. Item No. Designation Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 00-0000 Magnetic Sonde, Variants Raytheon Anschütz 00-0000 Magnetic Sondes Raytheon Anschütz see Fig. Nr. 01-0000 00-0000 Holders Raytheon Anschütz see Fig. Nr. 02-0000 00-0000 Installation Kit Raytheon Anschütz...
Page 66
Magnetic Sonde Illustrated Spare Parts Catalog Magnetic Sondes 01-0000, Sheet 1 of 1 4423 Edition:001...
Page 67
Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 01-0000 Magnetic Sondes Raytheon Anschütz 01-0000 Sonde, Magnetic Raytheon Anschütz 4004077 108-010.NG001 E01 Plastic Connector 01-0000 Sonde, Magnetic Raytheon Anschütz 4004081 108-010.NG002 E01 Ferrules 01-0000 Sonde, Magnetic Raytheon Anschütz 4004070 108-010.NG003 E01...
Page 68
Magnetic Sonde Illustrated Spare Parts Catalog Holders 02-0000, Sheet 1 of 1 4423 Edition:001...
Page 69
Magnetic Sonde Illustrated Spare Parts Catalog Fig. No. Item No. Designation Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 02-0000 Holders Raytheon Anschütz 02-0000 Holder Raytheon Anschütz 3609674 Single, Version for NG001, NG002, NG004 02-0000 Holder Raytheon Anschütz 3610884 Double, Version for NG003 02-0000 Holder...
Page 70
Magnetic Sonde Illustrated Spare Parts Catalog Installation Kit 03-0000, Sheet 1 of 1 4423 Edition:001...
Page 71
Magnetic Sonde Illustrated Spare Parts Catalog Fig. No. Item No. Designation Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 03-0000 Kit, installation Raytheon Anschütz 3610926 Only as a Set 03-0000 Bar, thread Raytheon Anschütz 3512666 148-345.00-008 / 43 x M4 03-0000 Bar, thread Raytheon Anschütz...
Page 72
Magnetic Sonde Illustrated Spare Parts Catalog Fig. No. Item No. Designation Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 03-0000 Nut, hexagon ISO4032-M4-A4-70 Raytheon Anschütz 1610305 03-0000 Screw, machine ISO4762-M3x6-A4-70 Raytheon Anschütz 1601186 03-0000 Screw, machine ISO4762-M4x14-A4-70 Raytheon Anschütz 1601237 4423 Edition:001...
Page 73
Magnetic Sonde Illustrated Spare Parts Catalog Intentionally left blank Edition:001 4423...
Page 74
Magnetic Sonde Illustrated Spare Parts Catalog Junction Boxes 04-0000, Sheet 1 of 1 4423 Edition:001...
Page 75
Magnetic Sonde Illustrated Spare Parts Catalog Fig. No. Item No. Designation Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 04-0000 Junction Boxes Raytheon Anschütz 04-0000 Box, junction Cassens & Plath CB 500JB For NG004, NG003 E01, Raytheon Anschütz 2011376 NG004 E01 04-0000 Box, junction...
Page 76
Magnetic Sonde Illustrated Spare Parts Catalog Special Tools and Test Equipment 05-0000, Sheet 1 of 1 4423 Edition:001...
Page 77
Magnetic Sonde Illustrated Spare Parts Catalog Fig. No. Item No. Designation Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 05-0000 Special Tool and Test Raytheon Anschütz Equipment 05-0000 Tool, operating Wago 280-434 Raytheon Anschütz 1722241 05-0000 Mask, centering Raytheon Anschütz 5024230 108-010.HP028 05-0000...
Page 78
Magnetic Sonde Illustrated Spare Parts Catalog Consumables 06-0000, Sheet 1 of 1 4423 Edition:001...
Page 79
Magnetic Sonde Illustrated Spare Parts Catalog Fig. No. Item No. Designation Manufacturer Manufacturer Part No. Remarks Supplier Supplier Part No 06-0000 Consumables Raytheon Anschütz 06-0000 Loctite 648 Henkel Typ 0648 Not illustrated Raytheon Anschütz 1970008 06-0000 Loctite 243 Henkel Typ 0243 Not illustrated Raytheon Anschütz 1970007...
Page 80
Magnetic Sonde Illustrated Spare Parts Catalog Intentionally left blank 4423 Edition:001...