Serial
No.
9
10
Edition: Sept. 13, 2005
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
Indications
Check connected course receivers (check of follow--up function) and check
of RoT.
The check of RoT is only possible at RoT--Indicators which are connected to
the Distribution Unit.
Switch B 37 (DIP switch)
OPEN
1 2 3 4 5
6 7 8
Check the fan, the display and the follow-up.
DO NOT PERFORM DURING HEATING STAGE!
The current course is displayed on the connected
course receivers.
Switch B 37 (DIP switch)
OPEN
1
2 3 4 5 6 7 8
Comments, Information
B 39
1X
Outer sphere turns cw
B38
1X
Outer sphere turns ccw
B39
1X
NOTE: If this function is activated during
the heating stage inadvertently,
the compass must switched
OFF and --ON again.
143
Compass
STD 22
130.1
129.9
129.8
129.7
129.6
130.1
130.2
130.3
130.4
130.5