Raytheon Anschütz STD 22 Compact GYRO COMPASS Installation And Service Manual page 130

Hide thumbs Also See for STD 22 Compact GYRO COMPASS:
Table of Contents

Advertisement

Serial
no.
12
Step 14
12
Step 15
12
Step 16
12
Step 17
12
Step 18
12
Step 19
12
Step 20
12
Step 21
12
Step 22
12
Step 23
12
Step 24
12
Step 25
3646/110--233.DOC010302
Installation and Service manual
Compass STD 22
Compass STD 22 Compact
DIP switch setting
Function
Indicate operating voltage (73VAC)
Nominal Value: <65.0...79.0V
Indicate DC operating voltage for 400Hz
(78 -- 79.5VDC)
Nominal value: 78V
Tolerance: <77.0...79.5V
Indicate gyro supply 54--56V
Nominal value:
During "start--up" 45...60V
During operation 53...58V
Indicate gyro current 160--250mA
Nominal value:
During "start--up" 150...400mA
During operation 120...350mA
Indicate operating voltage (13--17VDC)
Nominal value: <15.5V
Indicate internal operating voltage 15VDC
(14.5--15.5VDC)
Indicate internal operating voltage 24VDC
(23--35 VDC)
Indicate pump voltage 24V 50Hz
(24V +/-- 1V, 50 Hz)
Nominal value: 23.5...24.5V
Indicate pump current (150mA)
Nominal value: 140...180mA
Indicate pick--up voltage
(coded) <5mV
Indicate program number and software
version of the program for the
microprocessor on the sensor PCB.
Indicate program number and software
version of the program for the
microprocessor on the Power Supply PCB.
120
EFF
EFF
Edition: Feb. 17, 2006