The ship's electrical supply ( AC
terminal board at terminals 17 and 19 or 18 und 20 see Figure 24.
To connect the AC/DC Converter with a 24VDC load, use cables which meet the
following minimum requirements:
-- 2 x 2,5mm
-- 2 x 0,5mm
The output voltage (24VDC supply) is taken from the terminals:
6(24VDC) and 11(0V) or
7(24VDC) and 12(0V) or
8(24VDC) and 13(0V) or
9(24VDC) and 14(0V) .
Before connecting the 24VDC load to the AC/DC Converter, the output voltage must be
measured. It must be within the tolerance range of 18 VDC to 36 VDC.
After the ship's mains is switched on, the AC/DC Converter is supplied at 24VDC.
The AC/DC Converter does not need to be switched on separately.
Edition: Feb, 17, 2006
Installation and Service manual
Compass STD 22 Compact
To connect the cables to the terminal board, the plastic
cover has to be pulled off from the terminal board.
Cables should not be lengthened too long, to prevent a
short circuit to a neighbour terminal by an inadvertently
loosening.
Additionally the cable should be fixed (as shown in
Figure 24) with tie wraps and self adhesive tie mounts.
After that the plastic cover has to be pulled on the ter-
minal board.
IN
2
(with screen) gyro compass
2
(with screen) Additional Output Box
= 115...230V, 50/60Hz) must be connected to the
45
Compass
STD 22
3646/110--233.DOC010302