Omm-2 / Omi-2T / Omi-2H / Omi-2 / Omi / Omm Positioning; Performance Envelope With An Omm-2 / Omi-2T / Omi-2H / Omi-2; (Modulated Transmission); Omm-2 / Omi-2T / Omi-2H / Omi-2 - Renishaw OMP40-2 Installation Manual

Optical machine probe
Hide thumbs Also See for OMP40-2:
Table of Contents

Advertisement

OMP40-2 installation guide

OMM-2 / OMI-2T / OMI-2H / OMI-2 /

OMI / OMM positioning
To assist in finding the optimum position for the
OMM-2 / OMI-2T / OMI-2H / OMI-2, the signal
condition is displayed on a multi-coloured LED.
To assist in finding the optimum position for the
3.2
OMI, the signal strength is displayed on an OMI
multi-coloured LED.
To assist in finding the optimum position of the
OMM during system installation, signal strength
outputs are available on the MI 12 interface.
Performance envelope with an

(modulated transmission)

The probe and OMM-2 / OMI-2T / OMI-2H /
OMI-2 diodes must be in each other's field of view
and within the performance envelope shown. The
OMP40-2 performance envelope is based on the
OMM-2 / OMI-2T / OMI-2H / OMI-2 being at 0°
and vice versa.
OMP40-2
1 (3.3)
2 (6.5)
3 (9.8)
4 (13.1)
5 (16.4)
Typical plot at 20 °C (68 °F) 360° transmission around probe axis in m (ft)
75°
60°
45°
30°
15°
15°
30°
45°
60°
75°
30°
15°
15°
75°
60°
45°
OMM-2
1 (3.3)
2 (6.5)
30°
3 (9.8)
45°
4 (13.1)
60°
5 (16.4)
75°