1.2.9
Digital I/O Connector and Pin Definition
2 DI/ 2DO with optical isolation protection 2KV
DI: W et/Dry
DO: W et
DIO Design Specification
Input Channels
Input Voltage
Digital Input Levels for Dry
Contacts
Digital Input Levels for W et
Contacts
Output Channels
Output Current
On-state Voltage
DIO 2-IN/2-OUT of TB18 Female
The Agent 336-FL is supported an isolated 2-in/2-out Digital I/O (DIO)
Pin
Signal
1
COM+
2
OUT0
3
OUT1
4
COM-
Introduction
Digital Input
2,source type
0 to 24VDC
Logic level 0:Close to GND
Logic level 1:Open
Logic level 0:+10V to +24V (DI To COM-)
Logic level 1:+3V max.
Digital Output
2,sink type
Max. 200 mA per channel
24VDC nominal, open collector to 30V
Pin
Signal
5
Ext Power
6
IN 0
7
IN 1
8
GND
Agent336-FL Series User's Manual
5
Need help?
Do you have a question about the Agent336-FL Series and is the answer not in the manual?
Questions and answers