Installation Requirements - Zip Tudor Installation & Operating Instructions Manual

Single point open outlet (vented) under-sink water heaters
Table of Contents

Advertisement

WARNING
Please read all installation requirements, installation procedures and precautions before
!
installing any Zip Tudor water heater.
Never attempt to install the appliance without reading all of the applicable instructions.
For continued safety of this appliance it must be installed, operated and maintained in
accordance with the manufacturer's instructions.
This appliance may deliver water at high temperature. Refer to the plumbing code of
Australia (PCA), local requirements and installation instructions to determine if additional
delivery temperature control is required.
The appliance is recommended for sinks and tubs; not recommended for basins.
Zip Tudor water heaters are open outlet (vented) water heaters and must not be installed in
the same way as mains pressure type water heaters.
The outlet from any Zip Tudor water heater must be connected directly to an outlet spout
on the sink and must not be obstructed by a tap or valve or in any other way.
The water flow is controlled by a cold water tap connected before the water heater. Cold
water pushes hot water out of the tank when the cold water tap is turned ON. Any such
cold water tap should be labelled HOT.
This water heater must not be connected to more than one outlet.
All plumbing connections must be made in accordance with AS3500.
The appliance is intended only for indoor use and should never be installed outdoors or be
exposed to the elements of nature.
Over-sink and under-sink models are NOT interchangeable.
The appliance is unsuited for use by children or infirm people or those without experience;
unless they have been given supervision or instruction by a person responsible for their
safety. Children should be supervised to ensure they do not play with the heater.
If the power supply cord is damaged it must be replaced by a Zip Service Provider or a
qualified electrician.
Do not remove the cover of the heater under any circumstances without first isolating the
heater from the power supply.
Do not turn the power ON unless the appliance is filled with water.
Outlet temperature should be set to no greater than 50°C without due regard to regulations
governing the storage temperature of hot water.
The appliance must not be cleaned by a water jet.

Installation requirements

Before installing, ensure that the following are available:
a) sufficient space to position the heater so there is 270 mm clear access under the heater
(over-sink models) or 270mm above (under-sink).
b) standard 10 amp 240 volt power outlet within 1500 mm of the heater
c) cold water supply with a minimum working pressure of 100 kPa and a maximum working
pressure of 350 kPa.
d) Isolating valve (not supplied)
If the pressure may exceed 350 kPa, a 350kPa pressure limiting valve (not supplied) must
be installed in the cold water supply line.
A double check valve (not supplied) is required to comply with the backflow requirements of
AS/NZS3500.1
Under-sink models must be installed beneath approved vented mixer taps requiring a single
mounting point on a sink, or tub. (Not recommended for basins).