Pre-Installation
CHARACTERISTICS OF THE WATER SUPPLY
PARAMETER
Refer to the specific regulations
POTABILITY
SUPPLY
PRESSURE
HARDNESS
(TH)
for bromine treatments it is
pH
recommended to keep the pH in
ALKALINITY
80 and 125 mg/l (8-12.5°F)
(CAT)
OPTIMAL VALUES
between...
of the country of use
between 10°F and 25°F
(100 mg/l-250 mg/l)
the range 7.4 to 7.8
EN
VALUES ABOVE OR BELOW CAN...
...cause problems related to the safety and well-being of
users
maximum: 300,000 PA (3 bar)
minimum: 150,000 PA (1.5 bar)
...cause build-up that over time can cause damage to the
walls of the minipool, the pipes, the filter system, as well
as the heating unit and pumps. The limescale deposits
can also hide bacterial loads that are not easily reached by
disinfectant products. Installation mandatory.
It is mandatory to install a water softener, choosing the
model according to the hardness of the water.
...irritation of the eyes and skin of people in the water,
water with little sanitising power, excessive consumption
of chemicals, decrease in the duration of the minipool
components.
...more likely uncontrollable changes in pH
13