1. D ESIGN AND APPLICATION The MCT12E is a series of access terminals dedicated to RACS 5 system. Depending on their versions, devices enable identification of users by PINs and/or EM125kHz (UNIQUE) proximity cards. MCT12 is connected to access controller through RS485 interface. Terminal can be installed in outdoor locations without any additional protection measures.
Page 3
MCT12E Operating Manual 05.10.2020 Fig. 1 MCT supply from MC16 access controller Fig. 2 MCT supply from dedicated power supply unit RS485 bus The communication method with MC16 access controller is provided with RS485 bus which can encompass up to 16 devices of RACS 5 system, each with unique address in range of 100-115. The bus topology can be freely arranged as star, tree or any combination of them except for loop.
Page 4
(VISO). Inputs Terminals in –IO version e.g. MCT12E-IO offer 3 general purpose inputs of NO/NC type. Input types are defined within low level configuration (RogerVDM). Input functions are assigned within high level configuration (VISO).
Fig. 3 Tamper loop example Outputs Terminals in –IO version e.g. MCT12E-IO offer 2 transistor open collector type outputs (15V/1A rated) and 1 relay output with NO/NC contacts (30V/1.5A DC/AC rated). Electric parameters such as polarity are configured within low level configuration (RogerVDM). Function are assigned to outputs within high level configuration (VISO).
Page 6
MCT12E Operating Manual 05.10.2020 Blue IN2 input line White-yellow IN3 input line RS485 A Brown Brown RS485 bus, line A RS485 B Green-white White RS485 bus, line B White Green CLK line Green Yellow DTA line Yellow Pink Tamper contact...
MCT12E Operating Manual 05.10.2020 Note: New device is assembled with standard back panel with 23mm thickness but additional back panel with 35mm thickness is included. Such panel can be used if more space for connection cable is needed and it may also improve card reading distance if the terminal is mounted on metal surface.
MCT12E Operating Manual 05.10.2020 Fig. 7 Typical connection diagram for the –IO version terminal and MC16 access controller 4. C ONFIGURATION Low level configuration (RogerVDM) The purpose of low level configuration is to prepare device for operation in RACS 5 system.
Page 10
MCT12E Operating Manual 05.10.2020 Fig. 8 Connection to RUD-1 interface Table 5. List of low level parameters Communication settings RS485 address Parameter defines device address on RS485 bus. Range: 100-115. Default value: 100. RS485 communication timeout [s] Parameter defines delay after which device will signal lost communication with controller.
Page 11
KBD, CDI, BUZZER, LED OPEN, Parameter defines any text or comment which corresponds to the LED STATUS comment object. It is later displayed in VISO program. RACS CLK/DTA Terminal ID0 Settings in this area do not refer to standard MCT12E readers. 11/14...
MCT12E Operating Manual 05.10.2020 Note: Table 5 includes summary of parameters for all versions of MCT12E terminal. For instance keypad settings are not available for –BK version of terminals i.e. terminals without keypad. Manual addressing Manual addressing can be done within memory reset procedure.
EM 125 kHz access terminal; on-board I/Os MCT12E EM 125 kHz access terminal with keypad MCT12E-IO EM 125 kHz access terminal with keypad; on-board I/Os RUD-1 Portable USB-RS485 communication interface dedicated to ROGER access control devices 8. P RODUCT HISTORY Table 8. Product history Version...
Page 14
Weight of the equipment is specified in the document. Contact: Roger sp. z o.o. sp.k. 82-400 Sztum Gościszewo 59 Tel.: +48 55 272 0132 Fax: +48 55 272 0133 Tech.