5
Installation
5.3

Floor Load

The place of installation must be designed according to the specified floor load.
This consists of:
Static load = machine weight + max. solvent filling and
Dynamic load = cage centrifugal force with normally distributed, spin-damp garments.
Do not forget to take into account the centrifugal forces that arise during the spin processes,
according to the local conditions (ground, supporting walls, etc.).
No resonance is permitted.
Please consult building specialists.

5.3.1 Dimensions

M21-M26-M30
Depth*
Width*
Portion of the floor surface for force
transmission
Weight without solvent
Weight with solvent (stat. load)
Cage centrifugal force (dyn. load)
Floor load (stat. + dyn. load)
* Portion of the machine dimensions that is decisive for the size of the cage centrifugal force and
floor load.
** Calculated with:
-
21 kg (46.3 lb) or 26 kg (57.3 lb) or 30 kg (66.1 lb) load weight, with 50 % unevenly distributed
-
Mixed outer clothing
-
EBS
-
600 rpm
-
Solvent weight 0.77 kg/dm
Building specialists will find the best solution, from both a structural and economic point of view,
for the design of the foundation, taking into consideration the system or machine-related
conditions and the local particulars.
Use a load dispatcher frame if the permissible load for your floor is not sufficient.
17
17
M21
mm
1060
in
41.7
mm
2200
in
86.6
2
m
2.3
2
ft
24.8
kg
2120
lb
4674
kg
2500
lb
5512
N
18100**
lb
4070**
2
N/m
18500**
2
lb/ft
387
3
5
5.3
M26
M30
1190
1295
46.9
51.9
2200
2200
86.6
86.6
2.6
2.8
28.0
30.1
2270
2390 5270
5005
2700
2800 6174
5954
22400**
25900**
5040**
5820**
18800**
19200**
393*
400**