Technical Specifications
M21
Heating
Other:
Dist. throughput (DIN 11916) max.
Filter throughput
Filter surface, economy filter 1
Filter surface, economy filter 2
Weight without solvent
(with 2 economy filters, 2 cartridge filters)
Weight with solvent
(with 2 economy filters, 2 cartridge filters)
Floor space
Floor surface **
Cage centrifugal force
Floor load, stat. and dyn.
Noise level
Heat balance: *
Heat to dissipate
via cooling water ***:
Heat dissipated to the surroundings:
*
Values apply to a standard 2-bath load, 1st bath low level for distillation at
cooling water inlet temperature + 12 °C (21.6 °F), steam supply 4 – 5 bar (58.0 - 72.5 psi) overpressure
saturated steam, ambient temperature 5 to + 40 °C (5 to 104 °F)
**
For portion of the floor surface for force transmission, see Installation Instructions, Point. 5.3.1
***
Refers to water without additives
Subject to change!
40
40
l/h (US gal/h)
180 (47.5)
l/h (US gal/h)
2
2
m
(ft
)
5.0 (53.8)
2
2
m
(ft
)
3.5 (37.7)
kg (lb)
2120 (4674.6) 2120 (4674.6)
kg (lb)
2500 (5512.5) 2500 (5512.5)
2
2
m
(ft
)
3.3 (35.5)
2
2
m
(ft
)
2.3 (24.8)
N (lb)
18100 (4070)
2
2
N/m
(lb/ft
)
18500 (386)
dB (A)
kJ/cycle
kJ/cycle
9
Steam
Electric
5.0 (53.8)
3.5 (37.7)
3.3 (35.5)
2.3 (24.8)
18100 (4070)
18500 (386)
41400
11000
M21/M26/M30

Advertisement

Table of Contents
loading

This manual is also suitable for:

M26M30