Quiet Operation (Cooling Mode/Cooling Area Of Dry Mode); Quiet Operation (Heating) - Panasonic CS-Z20VKR Service Manual

Hide thumbs Also See for CS-Z20VKR:
Table of Contents

Advertisement

Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below
and the positions of the vane are as Figure 2 above.
Pattern
Airflow Direction Patterns at
Remote Control
Vane Angle (°) (Z20/25/35/42VK)
Vane Angle (°) (Z50/60/71/80VK)
* The vertical vane angle tolerance is within +/- 5 degree.

14.5 Quiet Operation (Cooling Mode/Cooling Area of Dry Mode)

Purpose
To provide quiet cooling operation compare to normal operation.
o
Control condition
Quiet operation start condition
o
When "POWERFUL/QUIET" button at remote control is pressed twice.
Quiet operation stop condition
o
When one of the following conditions is satisfied, quiet operation stops:
POWERFUL/QUIET button is pressed again.
Stop by OFF/ON switch.
Timer "off" activates.
Mild Dry button is pressed.
ECO button is pressed.
iAUTO-X button is pressed.
FAN SPEED button is pressed.
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
During quiet operation, if timer "on" activates, quiet operation maintains.
After off, when on back, quiet operation is not memorized.
Control contents
Fan speed is changed from normal setting to quiet setting of respective fan speed.
o
Fan speed for quiet operation is reduced from setting fan speed.
o
Outdoor fan speed is reduced from setting fan speed. (For Z42/50/60/71/80VK only)
o
Compressor frequency reduced.
o

14.6 Quiet Operation (Heating)

Purpose
To provide quiet heating operation compare to normal operation.
o
Control condition
Quiet operation start condition
o
When "POWERFUL/QUIET" button at remote control is pressed twice.
Quiet operation stop condition
o
When one of the following conditions is satisfied, quiet operation stops:
POWERFUL/QUIET button is pressed again.
Stop by OFF/ON switch.
Timer "off" activates.
A: swing
43.0°C
B: fix front
Indoor Heat Exchanger
Temperature
Figure 1
1
90
90
40.0°C
2
3
2
3
65
77.5
70
80
98
Top View
5
4
1
Figure 2
4
102.5
100
5
115
110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents