Panasonic CS-Z20VKR Service Manual page 22

Hide thumbs Also See for CS-Z20VKR:
Table of Contents

Advertisement

Indoor
Outdoor
Height
(I/D / O/D)
Width
Unit
(I/D / O/D)
Depth
(I/D / O/D)
Dimension
Height
(I/D / O/D)
PCKG.
Width
(Stacking
(I/D / O/D)
Condition)
Depth
(I/D / O/D)
Net (I/D / O/D)
Weight
Gross (I/D / O/D)
Stacking No. (CS / CU / CZ)
Pipe Diameter (Liquid / Gas)
Standard Length
Length Range (min – max)
I/D & O/D Height Different
Additional Gas Amount
Length for Additional Gas
Inner Diameter
Drain Hose
Length
Fin Material
Fin Type
Indoor Heat
Exchanger
Row x Stage x FPI
Size (W x H x L)
Fin Material
Outdoor
Fin Type
Heat
Row x Stage x FPI
Exchanger
Size (W x H x L)
Material
Air Filter
Type
Power Supply
Power Supply Cord
Thermostat
Protection Device
Cooling
Indoor Operation Range
Heating
Cooling
Outdoor Operation Range
Heating
1.
Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2.
Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb
(44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb).
3.
Heating low temperature capacity, Input Power and COP measured at 230V, indoor temperature 20°C, outdoor 2/1°C.
4.
Heating extreme low temperature capacity, Input Power and COP measured at 230V, indoor temperature 20°C, outdoor -7/-8°C.
5.
Specifications are subjected to change without prior notice for further improvement.
Model
POS (EAN)
Model
POS (EAN)
mm (inch)
302 (11-29/32) / 695 (27-3/8)
mm (inch)
1120 (44-1/8) / 875 (34-15/32)
mm (inch)
236 (9-5/16) / 320 (12-5/8)
mm (inch)
282 (11-1/8) / 796 (31-11/32)
mm (inch)
1190 (46-7/8) / 1049 (41-5/16)
mm (inch)
378 (14-29/32) / 460 (18-1/8)
kg (lb)
kg (lb)
Actual Stacking Condition (12 / 4 / -)
mm (inch)
6.35 (1/4) / 15.88 (5/8)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
mm
mm
Aluminium (Pre Coat)
mm
Aluminium (Blue Coat)
mm
36.4 x 651 x 904.5:874.5
Outdoor Power Supply
A
Dry Bulb
Maximum °C
32
Minimum °C
16
Maximum °C
30
Minimum °C
16
Maximum °C
46
Minimum °C
5
Maximum °C
24
Minimum °C
-15
CS-Z71VKR
5025232891115
CU-Z71VKR
5025232891412
13 (29) / 50 (110)
15 (33) / 54 (119)
5.0 (16.4)
3 (9.8) ~ 30 (98.4)
20 (65.6)
25 (0.3)
10 (32.8)
16.7
650
Slit Fin
2 x 17 x 21
836.5 x 357 x 25.4
Corrugated Fin
2 x 31 x 19
Polypropelene
One-touch
Nil
Electronic Contol
Electronic Contol
Wet Bulb
23
11
-
-
26
-
18
-
22
CS-Z80VKR
5025232891122
CU-Z80VKR
5025232891429
302 (11-29/32) / 795 (31-5/16)
1120 (44-1/8) / 875 (34-15/32)
236 (9-5/16) / 320 (12-5/8)
282 (11-1/8) / 894 (35-7/32)
1190 (46-7/8) / 1049 (41-5/16)
378 (14-29/32) / 485 (19-1/8)
13 (29) / 60 (132)
15 (33) / 66 (146)
Actual Stacking Condition (12 / 4 / -)
6.35 (1/4) / 15.88 (5/8)
5.0 (16.4)
3 (9.8) ~ 30 (98.4)
20 (65.6)
25 (0.3)
10 (32.8)
16.7
650
Aluminium (Pre Coat)
Slit Fin
2 x 17 x 21
836.5 x 357 x 25.4
Aluminium (Blue Coat)
Corrugated Fin
2 x 36 x 19
36.4 x 756 x 897.0:868.6
Polypropelene
One-touch
Outdoor Power Supply
Nil
Electronic Contol
Electronic Contol
Dry Bulb
Wet Bulb
32
23
16
11
30
-
16
-
46
26
5
-
24
18
-15
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents