Troubleshooting / FAQ

No power

If no lights are displayed on the SE-1000, when the power switch is in the On position, then there is no power
or insufficient power, getting to the unit.
Ensure that the power supply is connected to an appropriate AC mains outlet and that it is switched on.
Check the fuse in the AC mains cord. Ensure that the power supply you are using is the 12v 10A unit that is
supplied with the SE-1000. If you are running the SE-1000 from a Datavideo PD-1 Power Distribution Centre,
please ensure that you are using the special SE-1000 power adapter cable, and that both of the inlet cables
are connected to the PD-1.
No Video Output
Since the SE-1000 is unable to accept multiple input formats it is important that the input formats match the
intended output format. For example, you cannot put 1080/50i and take 576/50i out.
If you are feeding HD in then you must take HD out, or if you are feeding SD in you must take SD out.
Alarm Light is On
The Alarm Light can indicate that something is wrong with the fans, the power supply, or both the fan and the
power supply.
Check the status menu to see why the light is on (see page 25)
If the indication is FAN, check that the fans are not blocked or impeded and that there is sufficient ventilation
room around them.
If the indication is PWR, check that an appropriate power supply is being used (see No Power above)