16
KEY LOCK
(NO set by default)
This is used for locking the controls as a protection against undesirable interference of a foreign person.
Set YES/NO by turning the "
17
KEY CODE
This constant can be set if CONST 16 = YES. It is used for setting the code by which you will be able to
activate the controls. Set a four-digit combination (range from 0 to 9).
The keys will be locked within 1 minute (after opening the basic display). The "
the LCD. If you press the "
the correct code, you are able to make any changes (the controls are functional again). The controls will
automatically be locked again after you fi nish the setting (within approx. 1 min).
Gradually set 4 digits by turning the "
RECOMMENDATION:
18
BOILER INSPECTION REMINDER
Set the date on which you want to be informed about the necessity of the prescribed boiler service. At the
required time, the "MAINTENANCE NECESSARY" message and the "
tom line of the LCD (you can cancel the message by setting a new date for the next boiler maintenance!).
Gradually set the day, month and year by turning the"
19
PASSWORD
(not set by default)
It is used for locking the constants related to the given control settings. Suitable for service technicians.
After a numerical code has been entered, the user cannot change constants No. 4, 5, 6 and 10.
If you open the CONST mode and browse the constants, the "
locked; if you turn the "
stants remain locked. To try to unlock them again, you must exit the CONST mode and browse up the
constant locked again.
Turning the "
" button, gradually enter four digits and confi rm each setting with the "
VERSION (restoring the default settings)
20
Firmware version, informative parameter only.
If you press the "
" button long (for about 3 s), the RESET message appears shortly on the LCD and
the thermostat returns to the default settings!
QUICK CHANGE OF REQUIRED TEMPERATURE / PROGRAM IN THE AUTO MODE
Press twice the
" " ; the required temperature starts fl ashing on the display. Change the required tempera-
button and press the
ture by turning the "
"
SMS form: Temp xx (
Change of the desired temperature; the change will last until the next temperature change given
by the program.
Press thrice
the setting programm starts fl ashing on the display. Change it by turning
" ",
button and press the
"
QUICK CHANGE OF REQUIRED TEMPERATURE IN THE MANU MODE
Press twice the
" "; the required temperature starts fl ashing on the display. Change the required tempe-
rature by turning the "
" button and press the " "
change.
SMS form: Temp xx (
Change of the desired temperature; the change will be permanent.
OPERATIONAL HOURS
Push the "
" button four times. The boiler operating hours appear on the LCD. The fi gure on the picture
means 906 hours 43 minutes.
Resetting the counter:
When operational hours are displayed, turn the "
EXTERNAL SENSOR TEMPERATURE
Push the "
" button fi ve times. The current temperature of the external sensor appears on the LCD; the
value is only informative, and appears only if the external sensor is monitoring the maximum fl oor temperature
(see CONST 12, page 9).
" button and press the "
" or "
" button, the LCD asks you to enter the key code; after entering
" button; confi rm each setting with the "
- Record the key code in the table
- You can cancel the code by setting CONST 16 to NO, or by restoring the
default settings of the thermostat (see CONST 20).
- in case of loss of the code, it is necessary to bring the thermostat to factory settings using pressing
buttons RESET (see page 1) and MENU (will erase all settings changes).
(1.1.2032 set by default)
" button, the password is required! Unless you enter the password, the con-
.
"
"
The change will last until the next program change.
where xx are only integers within the range of CONST2 and CONST3)
.
"
.
The change will last until the next manual temperature
where xx are only integers within the range of CONST2 and CONST3)
" button anti-clockwise.
" button to confi rm.
" symbol will appear on the bot-
" button, confi rm each setting with the "
" symbol appears next to the constants
USER TIPS
" symbol appears on
" button.
".
".
"
"
16 LOCK
17 KEYCOdE
YOUR CODE
18 SERVICE dAY
19 PASSWORd
20 VERSION
TEMP. IN AUTO
TEMP IN MANU
OPER HOURS H.C.
TEMP 2Nd SENS