Remove the cleaning lid�
Vacuum the combustion residues off the flue gas collecting duct,
especially the area to the convection fan�
Open the rear side panel with the key for the ombustion chamber
door�
Unscrew the two wing nuts and remove the outer cleaning lid�
Vacuum the combustion residues off the flue gas collecting duct,
especially the area to the convection fan�
Install the removed parts in reverse order�
Note
Your stove may suck in false air via incorrectly sealed cleaning
covers; this air may lead to incomplete combustion in the fire
trough and thus piling up of pellets� DANGER of FIRE!
To ensure the proper operation of your pellet stove, replace any
defect (porous, frayed) seals after cleaning and maintenance�
There are 4 Allen screws to align the convection fins perfectly�

Cleaning the flue pipes

(annually)
Remove the flue pipes� Inspect and clean the chimney connection�
Brush off any soot and dust deposits in the fire and in the flue pipes
and vacuum�
Note
Accumulated fly ash in the flue gas channels may impair the
performance of the stove and pose a safety risk�