Cleaning and maintenance
50/73
4.8.2
Replace faulty UV low pressure lamps immediately.
Always replace the entire set of lamps after the specified operating time.
–
Turn 90° and carefully remove from the socket.
–
Low pressure lamps possess a reflector which directs the light outwards.
The lamps must be mounted in such a way that the rear side of the re-
flector is located on the device side.
–
Push the pins vertically into the socket from above.
18609 / 0
–
Turn the lamp 90°.
The lettering must be oriented towards the outside (i.e. towards the tan-
ning room or towards the user).
18610 / 0
Low pressure lamps
DANGER!
Danger of burns from hot lamps and surfaces!
Finger and hands may get burned when replacing lamps.
–
Before carrying out maintenance work, wait until the
device has cooled down sufficiently.