Available languages

DMX Address: 33
DMX512 Controller
effect panel are then automatically assigned to the following addresses.

3.8 ETHERNET

To enable Artnet mode, proceed as follows:
• Press the ENTER button to access the main menu.
• Press the UP/DOWN button to scroll the menu, select the Connect icon, then press the ENTER button to
enter the next menu Ethernet.
Press the UP/DOWN button to scroll through the menu, select Protocol, Universe, Start Channel, IP Address ,
Ethernet to DMX and press ENTER to activate the mode.

3.9 ID and RDM

With this function you can call up various submenus via RDM.
This device is RDM ready. RDM stands for "Remote Device Management" and makes remote control of
devices connected to the DMX-bus possible. Manual settings like adjusting the DMX starting address are
no longer needed. This is especially useful when the device is installed in a remote area. RDM is integrated
in DMX without influencing the connections. The RDM-data is transmitted via the standard XLR-poles 1
and 2 – new DMX-cables are not necessary. RDM ready and conventional DMX devices can be operated
in one DMX line. The RDM protocol sends own packages in the DMX512 data feed and does not influence
conventional devices. If DMX splitters are used and RDM control is to be used, these splitters must sup-
port RDM. The number and type of RDM parameters depend on the RDM controller (not included) is used.
• Press the ENTER button to access the main menu.
• Press the UP/DOWN button to scroll the menu, select the Connect icon, then press the ENTER button to
enter the next menu.
• Press the UP/DOWN button to scroll through the menu, and then select the RDM ID and press the ENTER
button to enter the next menu.
• Press UP/DOWN button to scroll through the menu, then select Password and press ENTER to confirm.
• Use the arrow keys to enter the password 050 and press ENTER to confirm.
• Once you have entered your password, you can set the PID Code, necessary to control the unit with the
RDM protocol. Press the UP/DOWN button to scroll through the menu, select PID Code and press EN-
TER to confirm.
• Use the arrow keys to enter the PID Code, then press the ENTER button to confirm your choice.
• Press the LEFT button repeatedly to exit the menu and save changes.
SUNBAR2500MAX
DMX Address: 37
DMX Address: 41
Fig.19 - Example 4 DMX channels configuration
DMX Address: 44