Important Safety Information; Insert Certification; Btu & Efficiency Specifications - Quadra-Fire 51I-ACC-BK Installation Manual

51-i acc wood insert automatic combustion control (acc)
Table of Contents

Advertisement

1

Important Safety Information

A. Insert Certification
Model: 5100-I (ACC) Insert
Laboratory: Intertek
Report No: 100323198PRT-001a
Solid Fuel Type, Listed Room
Type:
Appliance
UL1482 and ULC S628-93 and
Standard:
(UM) 84-HUD, Mobile Home
Approved.
NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the UL1482,
(UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S628-93 and CAN/CSA-B365 Installation Codes in
Canada.
The Quadra-Fire 5100 Wood Insert (ACC) meets the U.S. Environmental Protection Agency's crib wood emission limits
This wood appliance needs periodic inspection and repair for proper operation. Consult the owner's manual for further
information. It is against federal regulations to operate this wood heater in a manner inconsistent with the operating
instructions in the owner's manual.
January 13, 2020
B. BTU & Efficiency Specifications
for wood appliances sold after May 15, 2015.
Approved for ZC fireboxes.
7047-910J
EPA Certification #: 861
EPA Certified Emissions: 4.2 grams per hour
*LHV Tested Efficiency: 79.1%
**HHV Tested Efficiency: 73.2%
***EPA BTU Output: 10,500 to 27,854 / hr.
****Peak BTU/Hour
Output:
Vent Size: 6 inches
Firebox Size: 3 cubic feet
Recommended Wood
Length:
Fuel Orientation: Front-to-Back
Fuel Seasoned Cord Wood
* Weighted average LHV efficiency using Douglas Fir
dimensional lumber and data collected during EPA
emissions test.
**Weighted average HHV efficiency using Douglas
Fir dimensional lumber and data collected during EPA
emissions test.
***A range of BTU outputs based on EPA Default
Efficiency and the burn rates from the low and high EPA
tests, using Douglas Fir dimensional lumber.
****A peak BTU out of the appliance calculated using the
maximum first hour burn rate from the High EPA Test and
the BTU content of cord wood (8600) times the efficiency.
5100 Insert ACC
67,800
20 inches