4.1
Data Administrator
% If a wrong Administrator Password is entered for confirmation, a message appears that tells that
there is a mismatch in the Administrator Password. Enter the correct Administrator Password.
% If the Enhanced Security Mode is set to [ON], entry of a wrong password is counted as unauthorized
access. If a wrong Administrator Password is entered a predetermined number of times (once to
three times) or more set by the Administrator of the machine, a message appears that tells that the
machine accepts no more Administrator Passwords because of unauthorized access for any sub-
sequent entry of the Administrator Password. The machine is then set into an access lock state.
To cancel the access lock state, settings must be made by the Service Engineer; or, turn off, and
then turn on, the main power switch of the machine. If the main power switch is turned off and
on, the access lock state is canceled after the lapse of time set for [Release Time Settings]. When
the main power switch is turned off, then on again, wait at least 10 seconds to turn it on after turn-
ing it off. If there is no wait period between turning the main power switch off, then on again, the
machine may not function properly.
5
Check the data displayed on the SSL certificate check screen and click [Yes].