Kyocera KM-2810 Service Manual page 63

Hide thumbs Also See for KM-2810:
Table of Contents

Advertisement

Maintenance
item No.
Checking the DP sensors
U244
Description
Displays the status of the respective sensors in the DP.
Purpose
To check if respective sensors in the DP operate correctly.
Method
1. Press the start key.
2. Turn the respective sensors on and off manually to check the status.
When a sensor is detected to be in the ON position, the display for that sensor will be highlighted.
Display
TMG SW
SET SW
DP OP SW
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting the maintenance cycle
U250
Description
Displays and changes the maintenance cycle.
Purpose
To check and change the maintenance cycle.
Method
1. Press the start key. The currently set maintenance cycle is displayed.
Setting
1. Select [M.CNT A] using the cursor up/down keys.
2. Change the setting using the cursor left/right keys or numeric keys.
Description
Maintenance cycle
3. Press the start key. The value is set.
Clearing
1. Select [CLEAR] using the cursor up/down keys.
2. Press the start key. The count is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking/clearing the maintenance count
U251
Description
Displays, clears and changes the maintenance count.
Purpose
To check the maintenance count.
Also to clear the count during maintenance service (replacing the maintenance kit).
(See page 1-4-3, page 1-5-29 and page 1-5-30)
Method
1. Press the start key. The maintenance count is displayed.
Setting
1. Select [M.CNT A] using the cursor up/down keys.
2. Enter a count using the cursor left/right keys or numeric keys.
3. Press the start key. The count is set.
Clearing
1. Select [CLEAR] using the cursor up/down keys.
2. Press the start key. The count is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Sensors
DP timing sensor
DP original sensor
DP open/close sensor
Setting range
0 to 9999999
2H9-1
Initial setting
100000
1-3-37