Kyocera KM-2810 Service Manual page 194

Hide thumbs Also See for KM-2810:
Table of Contents

Advertisement

2H9
Connector
Pin
YC9
1
GND
Connected
2
+3.3V1
to the scan-
3
CPUCLK
ner PWB
4
CPUSI
5
CPUSO
6
CPUSEL
7
CPURDY
8
OVMONOUT
9
PAGESET
10
SEGSO
11
SSCKN
12
SEGSI
13
SSBSY
14
SSDIR
15
SEGIR
YC10
1
+24V3
Connected
2
GND
to the laser
3
PLGDRN
scanner unit
4
PLGRDY
5
PLGCLK
6
PDN
7
GND
8
VDON
9
VDOP
10
OUTPEN
11
SAMPLEN
12
+3.3V1
YC16
1
PILED
Connected
2
GND
to the MP
3
HANDSN
paper sen-
sor
YC17
1
+24V3
Connected
2
GND
to the main
3
MMOTRDYN
motor
4
MMOTCLK
5
REMOTEN
YC18
1
PILED
Connected
2
GND
to the paper
3
PAPER
sensor
YC19
1
PILED
Connected
2
GND
to the exit
3
EXITN
sensor
2-3-6
Signal
I/O
-
-
O
3.3 V DC
I
0/3.3 V DC (pulse) Serial communications clock signal
I
0/3.3 V DC (pulse) Serial communications data input
O
0/3.3 V DC (pulse) Serial communications data output
I
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Serial communications clock
O
0/3.3 V DC (pulse) Serial communications data input
I
0/3.3 V DC
I
0/3.3 V DC
I
0/3.3 V DC
O
24 V DC
-
-
O
0/3.3 V DC
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Polygon motor clock signal
I
0/3.3 V DC (pulse) Horizontal synchronizing signal
-
-
O
0/3.3 V DC (pulse) Video data signal (+)
O
0/3.3 V DC (pulse) Video data signal (-)
O
0/3.3 V DC
O
0/3.3 V DC
O
3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
24 V DC
-
-
I
0/3.3 V DC
O
0/3.3 V DC (pulse) Main motor clock signal
O
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
O
3.3 V DC
-
-
I
0/3.3 V DC
Voltage
Ground
3.3 V DC power source
Communications select signal
Communications ready signal
Communications ready signal
Vertical synchronizing monitor signal
Vertical synchronizing signal
Impossible transmission/Completion notice signal
Serial communications T/R switching signal
Serial communications interruption demand signal
24 V DC power source
Ground
Polygon motor: On/Off
Polygon motor ready signal
Ground
Laser output enable signal
Sample/hold timing switching signal
3.3 V DC power source
3.3 V DC power source
Ground
MP paper sensor: On/Off
24 V DC power source
Ground
Main motor ready signal
Main motor: On/Off
3.3 V DC power source
Ground
Paper sensor: On/Off
3.3 V DC power source
Ground
Exit sensor: On/Off
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents