2H9-1
Maintenance
item No.
Adjusting the scanner leading edge registration
U066
Description
Adjusts the scanner leading edge registration of the original scanning.
Purpose
Make the adjustment if there is a regular error between the leading edges of the copy image and original.
Adjustment
1. Press the start key.
2. Select the item to be adjusted using the cursor up/down keys.
Display
FRONT
TAIL
3. Press the system menu/counter key.
4. Place an original and press the start key to make a test copy.
5. Press the system menu/counter key.
6. Change the setting value using the cursor left/right keys or numeric keys.
For copy example 1, increase the value. For copy example 2, decrease the value.
7. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following adjustments in
maintenance mode.
U066
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-20
Description
Scanner leading edge registration
Scanner leading edge registration
(rotate copying)
Scanner leading edge registration
Original
U403
U071
(P.1-3-43)
(P.1-3-24)
Description
Setting
range
-45 to 45
-45 to 45
Copy
Copy
example 1
example 2
Figure 1-3-7
U404
(P.1-3-44)
Initial
Change in
setting
value per step
0
0.086 mm
0
0.086 mm