Stihl RMI 632 PC-L Instruction Manual page 32

Table of Contents

Advertisement

Available languages

Available languages

English
To connect the perimeter wire to an external docking station:
7
7
► Guide the perimeter wire (3) though the wire channel in
the base plate (7). Thread the perimeter wire into the wire
channels. If necessary, loosen the wire stakes.
► Insert the perimeter wire (3) into the wire channels in the
base plate and guide it through the port (4) to the rear of
the docking station.
5
► Cut the ends of the perimeter wire (5 and 6) so that
approximately 15.7 in. (40 cm) is available for insertion
into the docking station. Additional length is not needed.
► Do not coil excess wire behind the docking station.
Excess wire can interfere with the operation of the robotic
mower.
30
3
6
To connect the perimeter wire to the panel:
4
► Use a suitable tool to strip a = 0.236 in. (6 mm) from the
of the left perimeter wire (5) end and twist the perimeter
wire strands.
► Twist both perimeter wire ends together (5 and 6).
► Open the panel, @ 10.3.
5
8
► Press and open the left clamping lever (8).
► Insert the stripped perimeter wire end (5) into the clamping
block as far as it will go.
► Close the clamping lever (8).
► Use a suitable tool to strip a = 0.236 in. (6 mm) from the
end of the right perimeter wire (6) and twist the perimeter
wire strands.
10 Installing the Robotic Mower
5 + 6
a
5
a
6
0478-131-3052-A

Advertisement

Chapters

Table of Contents
loading

Table of Contents